检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Masataka Kitano Kazuto Fujimoto Atsuko Kato Ken-ichi Kurosaki Isao Shiraishi
机构地区:[1]Department of Pediatric Cardiology,National Cerebral and Cardiovascular Center,Osaka,Japan [2]Department of Pediatric Cardiology,Okinawa Prefectural Nanbu Medical Center&Children’s Medical Center,Okinawa Prefecture,Japan
出 处:《Congenital Heart Disease》2021年第3期269-283,共15页先天性心脏病(英文)
摘 要:Background:Although transcatheter closure of atrial septal defect(ASD)is safe and effective for patients with sufficient rim,ASD patients with absent and/or malaligned aortic and/or superior rim have higher risks of device embolization and cardiac erosion.We have treated such high-risk patients using a Figulla Flex II(FFII)device shaped flared and straddling behind the aorta because this method would avoid such serious complications.However,its long-term efficacy and safety remain unclear.Therefore,the midterm efficacy and safety of this method were studied.Methods:We retrospectively evaluated the outcome of 47 consecutive patients with such rim(age 6–73 years,weight 17–75 kg,31 females)treated with this method at our hospital between February 2016 and September 2019.To make the flared and straddling shape,we selected a FFII 4–6 mm larger than the balloon sizing diameter by stop-flow technique.We also studied the device shape,the disc pressure to the Valsalva wall and their changes over 6 months by transesophageal echocardiography.Results:All procedures were successful,and leakage disappeared within 1 year.During a mean follow up of 37±12 months,complications included a transient sinus node dysfunction and one I°atrioventricular block within 3 months.Whole device shape changed from bulky to thin:the device waist and thickness significantly decreased by around 1.5 mm and 3.5 mm,respectively(p<0.05),but the two discs remained flared and straddling behind the aorta over 6 months;therefore,the disc edges seldom pressed the Valsalva wall perpendicularly,even though the inner plane of either disc often slightly pressed the wall.Conclusions:ASD closure using a FFII shaped flared and straddling behind the aorta is probably effective and safe for patients with absent and/or malaligned aortic and/or superior rim although requiring care for conduction disorders.
关 键 词:Atrial septal defect catheter intervention device embolization cardiac erosion conduction disorder
分 类 号:R54[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222