摘 要:中频静止电源装置作为动力系统及通讯导航等系统供电的电源,肩负着海上安全航行的重要任务。中频电源的发展,经历了从早期简易的中频发电机组到后来的可控硅式变频电源的过程,成为目前新一代变频电源装置,广泛应用于航空及军用电子电气设备。随着中频电源设备的不断升级换代,对中频电源设备的安装及调试要求也越来越高,由此引发的故障现象也日益频繁。本文着重对中频静止电源装置的典型故障进行分析并给出解决方案,为后续解决相关设备故障问题提供参考。As the power supply of power system,medium frequency static power supply device shoulders the important task of safe navigation at sea.The development of medium frequency power supply has experienced a process from the early simple medium frequency generator set to the later silicon-controlled type frequency conversion power supply.Now,through the efforts of researchers,it has become a new generation of variable frequency power supply device,which has been widely used in aviation and military electronic and electrical equipment.However,with the continuous upgrading of medium frequency power supply equipment,the installation and debugging requirements of medium frequency power supply equipment are becoming higher and higher,and the resulting fault phenomenon is also frequent.This paper focuses on the analysis of the typical faults of medium frequency static power supply devices,proposes solutions,and provides some reference for the subsequent solution of related equipment fault problems.