作 者:王丹丹 吕雷 岳柳青 张冬林 WANG Dandan;LV Lei;YUE Liuqing;ZHANG Donglin(Research Institute of Shaanxi Yanchang Petroleum(Group)Co.,Ltd.,Xi'an Shaanxi 710065,China;Shaanxi Key Lab of Lacustrine Shale Gas Accumulation and Exploitation,Xi'an Shaanxi 710065,China;The Fifth Pipeline Transportation Branch of Shaanxi Yanchang Petroleum(Group)Co.,Ltd.,Xi'an Shaanxi 710600,China;Xiasiwan Oil Production Plant,Yanchang Oilfield Co.,Ltd.,Ganquan Shaanxi 716100,China)
机构地区:[1]陕西延长石油(集团)有限责任公司研究院,陕西西安710065 [2]陕西省陆相页岩气成藏与开发重点实验室,陕西西安710065 [3]陕西延长石油(集团)有限责任公司管道运输第五分公司,陕西西安710600 [4]延长油田股份有限公司下寺湾采油厂,陕西甘泉716100
出 处:《石油化工应用》2023年第5期33-36,56,共5页Petrochemical Industry Application
摘 要:针对陕北油田某撬装注水站采出污水回注处理加药管线堵塞、处理后水质不达标问题,通过系统分析水质和各水处理单元的处理效果,发现主要原因在于水处理药剂加量及加药工艺不合理、各水处理单元的设备运行制度不科学、不规范。采用优化水处理药剂加量、优化加药工艺和优化设备运行制度等措施,采出污水回注处理装置持续稳定运行,处理后水的各项指标能满足地层平均空气渗透率≤0.01μm^(2)的回注要求。In view of the blockage of the dosing pipeline for reinjection treatment of produced wastewater and substandard water quality from a skid mounted water injection station in northern Shaanxi oilfield,through systematic analysis of the water quality and the treatment effect of each water treatment unit,it is found that the main reasons are unreasonable water treatment agent dosage and dosing process,and unscientific and non-standard equipment operation system of each water treatment unit.By adopting measures such as optimizing the dosage of water treatment agents,optimizing the dosing process and optimizing the equipment operation system,the produced wastewater reinjection treatment device has been operating continuously and stably.The indicators of the treated water can meet the reinjection requirements of formation with average air permeability≤0.01μm^(2).
分 类 号:TE992.2[石油与天然气工程—石油机械设备]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229