检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:罗晨 喻锟[1] 曾祥君[1] 仝海昕 慕静茹 谢志成 邓军[2] LUO Chen;YU Kun;ZENG Xiangjun;TONG Haixin;MU Jingru;XIE Zhicheng;DENG Jun(National Key Laboratory of Disaster Prevention and Reduction for Power Grid(Changsha University of Science and Technology),Changsha 410114,China;Extra-High Voltage Transmission Company of CSG,Guangzhou 510663,China)
机构地区:[1]电网防灾减灾全国重点实验室(长沙理工大学),湖南长沙410114 [2]中国南方电网有限责任公司超高压输电公司,广东广州510663
出 处:《电力系统保护与控制》2023年第13期91-101,共11页Power System Protection and Control
基 金:国家自然科学基金项目资助(52037001,52207125);湖南省自然科学基金项目资助(2022JJ50187);湖南省教育厅项目资助(22A0231);湖南省研究生科研创新项目资助(CX20220858)。
摘 要:针对低压配电系统中单个用电负载支路串联电弧故障辨识困难的问题,提出一种基于高频重构信号和Bayes-XGBoost的低压电弧辨识方法。首先,搭建多支路、多负载类型的低压电弧故障真型实验平台,并采集相关数据。其次,基于故障前后主线路电流高频信号变化规律,提出信号微弱变化叠加法重构故障有效信号。最后,建立适用于单个负载支路电弧故障辨识的XGBoost模型,并采用Bayes算法对模型多个超参数进行优化。实验结果表明,所提方法在多种工况下对单个负载支路电弧故障具有较高的辨识准确率。与6种主流故障分析方法对比,所提方法在精度、训练速度和泛化能力等方面展现出了显著的优越性,有利于实现低压配电系统单个负载支路电弧故障的可靠辨识。There is a problem of difficult identification of series arcing faults in single power-using load branches in low-voltage distribution systems.Thus a low-voltage arc identification method based on high-frequency reconstructed signals and Bayes-XGBoost is proposed.First,a multi-branch,multi-load type LV arc fault true type experimental platform is built and relevant data is collected.Second,based on the main line current high frequency signal change law before and after a fault,the signal weak change superposition method is proposed to reconstruct the effective signal of the fault.Finally,an XGBoost model for single load branch arc fault identification is established,and the Bayes algorithm is used to optimize several hyperparameters of the model.The experimental results show that the proposed method has a high accuracy in identifying arc faults in a single load branch in a variety of operating scenarios.In comparison with the six mainstream fault analysis methods,the proposed method shows significant advantages in terms of accuracy,training speed and generalizability.The proposed method is useful for the reliable identification of arcing faults in single load branches of LV distribution systems.
关 键 词:低压系统 XGBoost 支路电弧故障 特征提取 信号重构
分 类 号:TM501.2[电气工程—电器] TP18[自动化与计算机技术—控制理论与控制工程]