摘 要:5G基站设备高功耗及不同网络设备用电、备电差异化的特点,给通信基站建设、运营及能源管理带来了巨大挑战。在阐述通信基站供电系统总体架构的基础上,详细分析了5G基站差异化用电、差异化备电和基站节能等差异化能源管理方案,总结了各方案的优势与不足,并对5G基站差异化能源管理应用进行展望。The high power consumption of 5G base station equipment and the differentiation of power utilization and backup power for different network devices have brought huge challenges to the construction,operation,and energy management of communication base station.On the basis of elaborating on the overall architecture of the communication base station power supply system,a detailed analysis was conducted on differentiated energy management schemes such as 5G base station differentiated power consumption,differentiated backup power,and base station energy conservation.The advantages and disadvantages of each scheme were summarized,and the application of 5G base station differentiated energy management was prospected.