对纳氏试剂分光光度法测定水质氨氮的测定上限的实验研究  被引量:3

Experimental Study on the Upper Limit of Determining Ammonia Nitrogen in Water Quality by Nessler's Reagent Spectrophotometer

在线阅读下载全文

作  者:柴江君 Chai Jiangjun(Wanzijian Testing Technology(Shanghai)Co.,Ltd.,Shanghai 201800,China)

机构地区:[1]万子健检测技术(上海)有限公司,上海201800

出  处:《皮革制作与环保科技》2023年第11期23-26,共4页Leather Manufacture and Environmental Technology

摘  要:在实际水样中,氨氮的浓度变化较大,《水质氨氮的测定纳氏试剂分光光度法》(HJ 535-2009)[1]中氨氮的测定上限为2.00 mg/L(以N计),超过测定上限的样品往往需要进行稀释后重新检测,影响了检测工作的效率。为提高检测工作效率,本文对氨氮的测定上限进行了实验研究。研究结果表明,当氨氮含量在0.00~200.00μg时,所绘制的校准曲线满足检测工作使用要求;精密度和准确度测试结果符合氨氮检测的技术要求。因此,将氨氮的测定上限从2.00 mg/L提高到4.00 mg/L是合理可行的。The concentration of ammonia nitrogen in actual water samples varies greatly,and the upper limit for the determination of ammonia nitrogen in standard HJ 535-2009~([1])is 2.00 mg/L(measured in N),samples exceeding the upper limit often need to be diluted and retested,which affects the efficiency of the detection work.In order to improve the efficiency of detection work,this article conducted experimental research on the upper limit of ammonia nitrogen determination.The research results indicate that when the ammonia nitrogen content is between 0.00~200.00μg,When the calibration curve drawn meets the requirements for testing work;The precision and accuracy test results meet the technical requirements for ammonia nitrogen detection.Therefore,it is reasonable and feasible to increase the upper limit of ammonia nitrogen determination from 2.00 mg/L to 4.00 mg/L.

关 键 词:氨氮 纳氏试剂法 测定上限 蒸馏法 水质 