某电厂2号锅炉低温再热器悬吊管泄漏原因分析  被引量:1

Analysison leakage causes of suspension tube of cold reheater in a power plant No.2 boiler

在线阅读下载全文

作  者:徐亮[1] 王海琦 XU Liang;WANG Haiqi(Harbin Boiler Company Limited,Harbin 150046,China)

机构地区:[1]哈尔滨锅炉厂有限责任公司,黑龙江哈尔滨150046

出  处:《锅炉制造》2023年第4期18-20,共3页Boiler Manufacturing

摘  要:某电厂锅炉运行时67m炉右低温再热器区域发生泄漏,次日补水量突然增大,负荷无法稳定,被迫停炉。本文通过对泄漏位置进行宏观检查、化学成分分析、室温拉伸性能检测、硬度检测及金相分析,得出导致该区域超温泄漏的原因,为锅炉实际运行提供借鉴。The cold reheater on the right side of 67m furnace in a power plant leaked when the boiler was in operation.The next day,the water supply suddenly increased,and the load could not be stabilized,so the furnace was forced to stop.This article through macro-examination,chemical composition analysis,tensile property test at room temperature,hardness test and metallographic analysis of the leak location,the causes leading to over-temperature and leakage in this area are obtained,serve as a reference for boiler operation.

关 键 词:低温再热器 12Cr1MoVG材料 超温 爆管 

分 类 号:TK228[动力工程及工程热物理—动力机械及工程]

 