摘  要:电梯检验中,125%载荷试验是为了验证钢丝绳和轿厢的滑行距离是否符合TSG T7001-2009(含1、2号修改单)(以下简称“检规”)中8.11项及8.13项的要求。文中针对一起电梯载荷制动试验中滑行距离过大案例进行探讨,供检验和维护保养时参考。In elevator inspection,the 125%load test is to verify whether the sliding distance of the wire rope and car conforms to the requirements of item 8.11 and 8.13 in TSG T7001-2009(including Amendment No.1 and No.2)(hereinafter referred to as"Inspection Regulations").In this paper,a case of excessive sliding distance in an elevator load test is discussed for reference in inspection and maintenance.