检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王洪亮 冯雨 李云屹 马屹松 于明锐 刘卓 韩旭 郭强 元一单 WANG Hongliang;FENG Yu;LI Yunyi;MA Yisong;YU Mingrui;LIU Zhuo;HAN Xu;GUO Qiang;YUAN Yidan(CNNC Key Laboratory on Severe Accident in Nuclear Power Safety,China Nuclear Power Engineering Co.,Ltd.,Beijing 100840,China)
机构地区:[1]中国核电工程有限公司中核核电安全严重事故研究重点实验室,北京100840
出 处:《哈尔滨工程大学学报》2023年第7期1169-1174,共6页Journal of Harbin Engineering University
摘 要:极端气象条件可能会导致模块化小型压水堆核电厂(ACP100)出现倾斜风或进风口堵塞情况,探究其对非能动安全壳空气冷却系统换热能力的影响意义重大。本文在风洞平台内搭建模块化小型压水堆核电厂小比例模型并采用ANSYS FLUENT对原厂模型进行数值模拟。试验表明:各倾斜风条件下,环境风场对非能动安全壳空气冷却系统换热均是有利的;各进风口阻塞条件下,非能动安全壳空气冷却系统均可建立循环,无倒流或旁通现象;倾斜风、进风口阻塞耦合条件下,循环亦可建立。数值模拟表明:各倾斜风条件下,环境风场对非能动安全壳空气冷却系统换热均是有利的,换热增强11.3%~33.9%;各进风口阻塞条件下,非能动安全壳空气冷却系统换热最大削弱4.5%;而倾斜风、进风口阻塞耦合条件下,换热最大削弱7.7%。Extreme weather may lead to inclined wind or air inlet blockage in a modular,small,pressurized water reactor nuclear power plant(ACP100),and exploring its impact on the heat transfer capacity of passive containment air cooling systems is of considerable importance.The ACP100 small-scale model was built in the wind tunnel platform,and ANSYS FLUENT was used to simulate its prototype model.The experimental results show that the environmental wind field is beneficial to the heat transfer performance of a passive containment air cooling system under all types of inclined wind conditions.A passive containment air cooling system cycle can be established under air inlet blockage conditions,and bypass and backward flow are absent.In addition,the cycle can still be established under the coupling condition of inclined wind and air inlet blockage.Numerical simulation results show that under inclined wind conditions,the environmental wind field serves to enhance the heat transfer performance of the passive containment air cooling system as the heat transfer capacity is increased by 11.3%~33.9%.The heat transfer performance of the passive containment air cooling system is mostly weakened by 4.5%under air inlet blockage conditions.Meanwhile,the heat transfer performance is mostly weakened by 7.7%under the coupling conditions of inclined wind and air inlet blockage.
关 键 词:极端气象条件 模块化小型压水堆核电厂 倾斜风 阻塞 非能动安全壳空气冷却系统 小比例模型 数值模拟 换热
分 类 号:TL364[核科学技术—核技术及应用]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.43