海水换热器串流故障分析及解决  

Analysis and Solution of Internal Leakage Fault of Seawater Heat Exchanger

在线阅读下载全文

作  者:赵威 张宁[1] 曹志兴 梁波 ZHAO Wei;ZHANG Ning;CAO Zhi-xing;LIANG Bo(CNOOC Energy Technology&Services-Oil Production Services CO.,Tianjin 300452,China)

机构地区:[1]中海油能源发展股份有限公司采油服务分公司,天津300452

出  处:《辽宁化工》2023年第7期989-991,998,共4页Liaoning Chemical Industry

摘  要:海水换热器作为FPSO原油处理系统中的原油冷却装置,对原油处理、储存、外输至关重要。针对海水换热器在使用中出现的串流故障,提出了现场应急处理办法,并且对产生串流故障的原因展开了分析,制定了下一步检修计划,为海上油田同类型的海水换热器故障检修提供了参考依据。As the crude oil cooling device in the FPSO crude oil processing system,the seawater heat exchanger is very important for crude oil processing,storage and transportion.When the seawater heat exchanger is in use,the phenomenon of cross flow often occurs.In this paper,the on-site treatment method was put forward,and the reasons for the cross flow were analyzed,and the next maintenance plan was formulated,providing some reference for troubleshooting the same type of seawater heat exchanger in offshore oil fields.

关 键 词:FPSO 海水换热器 串流 

分 类 号:TK172[动力工程及工程热物理—热能工程]

 