Numerical investigation of impinging jet ventilation in ICUs:Is thermal stratification a problem?  被引量:1

在线阅读下载全文

作  者:Lei Wang Zhiqiang Wang Sirui Zhu Zhe Zhu Tao Jin Jianjian Wei 

机构地区:[1]Institute of Refrigeration and Cryogenics/Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province,Zhejiang University,Hangzhou,China [2]Center for Balance Architecture,Zhejiang University,Hangzhou,China [3]The Architectural Design&Research Institute of Zhejiang University Co,Ltd,Hangzhou,China [4]Zhejiang Modern Architectural Design and Research Institute Co,Ltd,Hangzhou,China

出  处:《Building Simulation》2023年第7期1173-1185,共13页建筑模拟(英文)

基  金:supported by the National Natural Science Foundation of China(52178092);the Basic Research Funds for the Central Government"Innovative Team of Zhejiang University"under contract number(2022FZZX01-09).

摘  要:Intensive care units(ICUs)are the high incidence sites of hospital-acquired infections,where impinging jet ventilation(IJV)shows great potential.Thermal stratification of IJV and its effect on contaminants distribution were systematically investigated in this study.By changing the setting of heat source or the air change rates,the main driving force of supply airflow can be transformed between thermal buoyancy and inertial force,which can be quantitatively described by the dimensionless buoyant jet length scale(l_(m)^(-)).For the investigated air change rates,namely 2 ACH to 12 ACH,l_(m)^(-)varies between 0.20 and 2.80.The thermal buoyancy plays a dominant role in the movement of the horizontally exhaled airflow by the infector under low air change rate,where the temperature gradient is up to 2.45℃/m.The flow center remains close to the breathing zone of the susceptible ahead,resulting into the highest exposure risk(6.6‰for 10-μm particles).With higher heat flux of four PC monitors(from 0 W to 125.85 W for each monitor),the temperature gradient in ICU rises from 0.22℃/m to 1.02℃/m;however,the average normalized concentration of gaseous contaminants in the occupied zone is reduced from 0.81 to 0.37,because their thermal plumes are also able to carry containments around them to the ceiling-level readily.As the air change rate was increased to 8 ACH(l_(m)^(-)=1.56),high momentum weakened the thermal stratification by reducing the temperature gradient to 0.37℃/m and exhaled flow readily rose above the breathing zone;the intake fraction of susceptible patient located in front of the infector for 10-μm particles reduces to 0.8‰.This study proved the potential application of IJV in ICUs and provides theoretical guidance for its appropriate design.

关 键 词:impinging jet ventilation heat sources air change rates respiratory particles lock-up phenomenon 

分 类 号:O35[理学—流体力学]

 