检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张永方 武力 李鹏 ZHANG Yongfang;WU Li;LI Peng(Beijing Triumph International Engineering Co.,Ltd.,Beijing 100024)
出 处:《中国建材科技》2023年第3期84-89,共6页China Building Materials Science & Technology
基 金:工信部科研项目(2015-0947T-JC)。
摘 要:介绍了第一批预应力损失的计算原理,利用变形协调条件对筒仓结构预应力第一批损失进行了理论推导,对不同曲率半径的筒仓进行试算,并与常用简化计算方法进行对比。结果表明,忽略直线段反向摩擦力时,σ_(l1max)计算结果偏差较大;σ_(l 2 max)精度要求不高时,可采用广义夹角按GB 50010-2010公式近似计算。结合设计经验,总结出不同成孔方式的预应力筋在计算σ_(l1)时的θ角限值及第一批预应力损失总值的计算方法。The calculation principle of prestress loss during stretching and anchoring stage is introduced.Based on the deformed compatibility,the prestress loss of silos is calculated theoretically.The trial results with different curvature radii based on theory method and common simplified calculation method are compared.The results show that the deviation ofσ_(l1max )calculated results is significant if the reverse friction of straight line segment is ignored.If the accuracy requirement is not high,the approximate calculation method of GB 50010-2010 can be adopt to solve σ_(l 2 max).Based on design experience,θlimit value used to solve σ_(l1) with different pore forming methods and calculation method of gross value of prestress loss during stretching and anchoring stage are summed up.