摘  要:某型光电跟踪仪在暗室进行电磁兼容测试时,测试结果显示其电源线传导发射(CE102)和电场辐射发射(RE102)这两项不满足限值要求。对此进行了深入剖析,并结合该设备的具体情况提出了相应的改进措施。将改进后的设备进行了测试,测试结果满足标准限值要求,验证了改进措施的有效性。During the electromagnetic compatibility test of a photoelectric tracker in a dark room,the test results show that the power line conduction emission(CE102)and electric field radiation(RE102)emission do not meet the limit requirements.This paper makes an in-depth analysis on this,and puts forward the corresponding improvement measures based on the specific conditions of the equipment.The improved equipment is tested,and the test results meet the requirements of the standard limit,which verifies the effectiveness of the improved measures.

关 键 词:光电跟踪仪 电磁兼容性 CE102 RE102 改进设计 