离子膜法制碱装置节能降耗措施  

Energy saving and consumption reducing measures for ion-exchange membrane alkali production equipment

在线阅读下载全文

作  者:高慧玲 曹双宇 李冉 陈婷 GAO Huiling;CAO Shuangyu;LI Ran;CHEN Ting(Wanhua Chemical Group(Yantai)Chlor-Alkali Thermal Power Co.,Ltd.,Yantai 264006,China)

机构地区:[1]万华化学(烟台)氯碱热电有限公司,山东烟台264006

出  处:《氯碱工业》2023年第7期12-15,共4页Chlor-Alkali Industry

摘  要:将旭化成电解槽升级为旭化成西格玛电解槽,同时更换离子膜,改造后吨碱电耗下降约152 kW·h/t,共节电1 820万kW·h/a;将蓝星(北京)化工机械有限公司电解槽更换极网,同时更换离子膜,吨碱电耗下降约201 kW·h/t,节电5 000万kW·h/a。用约克机组替代溴化锂机组,节约过热蒸汽11.3万t/a。同时进行其他升级改造,优化控制模式等措施,实现降低能耗的目标。Asahi Kasei electrolyzers were upgraded to Sigma electrolyzers and the ion-exchange membrane was replaced at the same time,which decreased the power consumption per ton of alkali by about 152 kW.h/t and savd a total of 18.2 million kW.h/a.After replacing the electrode mesh and ion membrane of the electrolytic cell produced by Blue Star(Beijing)Chemical Machinery Co.,Ltd.,the power consumption per ton of alkali decreased by about 201 kW:h/t,saving 50 million kW·h/a.The replacement of lithium bromide unit with York unit saved 113000 t/a of superheated steam.At the same time,other upgrades,improvements,and optimization of control modes were carried out,achieving the goal of reducing energy consumption.

关 键 词:氯碱装置 离子膜法电解 电解槽 离子膜 冷冻机组 能耗 

分 类 号:TQ114.262[化学工程—无机化工]

 