作 者:田彪 韦荫新 张小飞[1] 吴健 周威剑 TIAN Biao;WEI Yinxin;ZHANG Xiaofei;WU Jian;ZHOU Weijian(College of Civil and Architectural Engineering,Guangxi University,Nanning 530004,Guangxi,China;Xijiang Water Conservancy Comprehensive Technology Center,Xijiang Bureau,Zhujiang Water Conservancy Commission,Nanning 530007,Guangxi,China;Qinnan District Transportation Bureau of Qinzhou City,Guangxi,Qinzhou 535000,Guangxi,China)
机构地区:[1]广西大学土木建筑工程学院,广西南宁530004 [2]珠江水利委员会西江局西江水利综合技术中心,广西南宁530007 [3]广西珠钦州市钦南区交通运输局,广西钦州535000
出 处:《水力发电》2023年第8期60-64,共5页Water Power
基 金:国家自然科学基金资助项目(51809051)。
摘 要:基于内聚力理论并结合有限元法,以邕宁水利枢纽拦河闸坝为例,分析了闸墩的开裂和裂纹分布,获得了闸墩开裂荷载、初始裂纹位置、开裂范围和裂纹宽度等局部信息。研究表明,型钢混凝土闸墩的裂纹最先在闸门挡水侧牛腿的上、下角点产生,随着施加荷载增大,牛腿闸门支撑面与墩体交线布满裂纹,并从上、下角点沿着墩体和牛腿支座上、下交线扩展;在对称荷载和非对称荷载作用下,型钢混凝土闸墩的开裂荷载/设计荷载分别约为0.656和0.624;1倍设计荷载作用下的最大裂纹宽度均小于0.3 mm,型钢混凝土闸墩的抗裂性能满足相关规范对结构裂纹宽度限值的规定。Based on cohesion theory and finite element method,the gate dam of Yongning Water Conservancy Project is taken as the research case to analyze the cracking and crack distribution of gate pier.The local information such as cracking load,initial crack position,cracking range and crack width in gate pier is obtained.The research shows that,(a)the cracks in steel reinforced concrete pier are first generated at the upper and lower corners of corbel on the water retaining side of gate,and with the increase of applied loads,the intersection line between the support surface of corbel gate and the pier body is full of cracks,and these cracks extend from the upper and lower corners along the upper and lower intersections of pier body and corbel support;(b)under the action of symmetrical and asymmetrical loads,the cracking load of the steel reinforced concrete pier is about 0.656 and 0.624 times of the design load respectively;and(c)the maximum crack width under design load is less than 0.3 mm,which indicated that the cracking resistance of steel reinforced concrete pier meets the requirements of relevant specifications for the structural crack width limit.
分 类 号:TV662.2[水利工程—水利水电工程] TU398.7[建筑科学—结构工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145