检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王海锋 李新城 秦铁男 张馨予 封加全 宋神友 黄一[1] 徐云泽[1,4] WANG Hai-feng;LI Xin-cheng;QIN Tie-nan;ZHANG Xin-yu;FENG Jia-quan;SONG Shen-you;HUANG Yi;XU Yun-ze(School of Naval Architecture and Ocean Engineering,Dalian University of Technology,Liaoning Dalian 116024,China;Dalian Kingmile Anticorrosion Technology Co.,Ltd.,Liaoning Dalian 116024,China;Shenzhen-Zhongshan Link Admini-stration Center,Guangdong Zhongshan 528400,China;State Key Laboratory of Structural Analysis for Industrial Equipment,Liaoning Dalian 116024,China)
机构地区:[1]大连理工大学船舶工程学院,辽宁大连116024 [2]大连科迈尔防腐科技有限公司,辽宁大连116024 [3]深中通道管理中心,广东中山528400 [4]工业装备结构分析国家重点实验室,辽宁大连116024
出 处:《装备环境工程》2023年第7期117-126,共10页Equipment Environmental Engineering
基 金:广东省重点领域研发计划(2019B111105002);国家自然科学基金(52001055)。
摘 要:目的确定高纯锌、钛以及铂等3种参比电极在不同工况下的稳定性差异,以及不同参比电极针对沉管的最佳使用位置。方法以银/氯化银参比电极的监测电位数据为钢壳的实际电位基准,通过在不同区域设计安装电位传感器,持续监测沉管不同区域的钢壳电位,以及9个多月的波动情况。结果高纯锌参比电极所监测数据的变化趋势与钢壳实际电位数据接近,且环境介质的改变对其监测电位数值的影响不大,电位数据波动小。铂和钛参比电极在钢壳底面海泥/抛石耦合的服役环境下,其监测电位数据稳定,但是二者在海水中监测电位时,对环境介质中的溶解氧浓度、金属离子等氧化性介质较为敏感,极易受到氧化性介质的影响,导致测得的电位偏移剧烈。结论高纯锌参比电极更适合应用于沉管侧面阴极保护电位的长期监测,铂和钛参比电极更适用于钢壳底部保护电位的长期测量。The work aims to compare the stability of three reference electrodes made of high-purity zinc,titanium and platinum under various working conditions,and further determine where these electrodes should be positioned in the sinking tube for better performance.With the potential data measured through the Ag/AgCl reference electrode as the actual potential reference,the potential of the steel shell at different locations of the sinking tube was continuously monitored by the potential sensors installed in different areas for more than 9 mouths.The potential measured by the high-purity zinc reference electrode was close to the actual potential of the steel shell,and the change of the environment had little affect to the monitored results.Therefore,the high-purity zinc reference electrode could be used for the accurate measurement of the cathodic protection potential of steel shell surface.On the other side,the potential monitored by the platinum and titanium reference electrodes were stable under the environment of the sea mud/throwing stone at the bottom of the steel shell.However,the accuracy of these two electrodes could be easily affected by the oxidizing medias such as the dissolve oxygen,the metal ions,etc.,resulting in large deviations in the measurement results.Therefore,high-purity zinc reference electrode is more suitable for long-term monitoring of cathodic protection potential on the side of the sinking tube,while platinum and titanium reference electrodes are more suitable for long-term measurement of protection potential at the bottom of the steel shell.
分 类 号:TG172[金属学及工艺—金属表面处理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.148.217.16