Fault Propagation Mechanism of Hybrid Microgrid with Neutral Grounding of DC Side Capacitor

在线阅读下载全文

作  者:张一 张佰富 韩肖清[1] 任春光[1] 赵智博 Zhang Yi;Zhang Baifu;Han Xiaoqing;Ren Chunguang;Zhao Zhibo(Shanxi Key Laboratory of Power System Operation and Control Taiyuan University of Technology,Taiyuan 030001,China;School of Resources and Geosciences China University of Mining and Technology,Xuzhou 221000,China)

机构地区:[1]电力系统运行与控制山西省重点实验室(太原理工大学),太原030001 [2]中国矿业大学资源与地球科学学院,徐州221000

出  处:《电工技术学报》2023年第15期4208-4220,共13页Transactions of China Electrotechnical Society

基  金:国家自然科学基金联合基金重点项目(U1910216);山西省基础研究计划青年科学研究项目(202203021212288)资助。

摘  要:交直流混合微电网因其高效的新能源消纳性能,成为未来电网的重要发展形式。然而交直流混合微电网的互联结构使其故障响应更为复杂,严重影响微电网安全运行能力。该文基于双向功率变换器连接交流子网和直流子网的交直流混合微电网结构,针对故障引起的交互影响问题展开研究。首先选取交流子网和直流子网的典型故障情况,分析故障分量在子网间传播引起的谐波频次变化和故障回路的暂态过程;然后,分别推导交直流子网电气量在考虑系统互联结构下的表达式,得出非故障子网对故障的响应结果,揭示混合微电网故障传播机理;最后基于Matlab/Simulink平台搭建交直流混合微电网模型,并针对不同故障类型进行仿真分析,以验证推导的正确性。The AC-DC hybrid microgrid will become an important development form of the future power grid due to the efficient renewable energy consumption performance.However,the interconnection structure of AC-DC hybrid microgrid complicates the fault response and decreases the system robustness.In this paper,the typical structure of hybrid microgrid includes AC sub-grid,DC sub-grid,and a bidirectional power converter(BPC),and the response characteristics of non-fault sub-grid to fault are analyzed.The systematic and complete fault response characteristic analysis results can provide a theoretical basis for the design of hybrid microgrid cooperative control or cooperative protection strategy under fault conditions.The harmonic frequency change principle and the transient process of the fault loop caused by the propagation of fault components between sub-grids under typical fault conditions are analyzed in this paper.On this basis,the voltage and current expressions of the AC and DC sub-grids are deduced respectively with the consideration of the system interconnection structure.And then,the response results of the non-faulty sub-grid to the faulty sub-grid are obtained,which reveals the fault propagation mechanism of the hybrid microgrid.In the state of AC sub-grid fault,the harmonic transformation process caused by the propagation of negative sequence components and zero sequence components generated by symmetrical faults and asymmetric faults through BPC is deeply analyzed,and the general harmonic transformation expression is given.For the inter pole short-circuit fault and single pole grounding fault of DC sub-grid,this paper analyzes the transient process of short-circuit current loop in different stages,and deduces the expression of AC short-circuit current affected by DC sub-grid faults.The magnitude of the short-circuit current under a single-pole grounding fault is related to the BPC switch state.And the short-circuit current is characterized in the form of a piecewise function,by dividing the switch state of BPC,F

关 键 词:交直流混合微电网 双向功率变换器 故障传播 机理分析 

分 类 号:TM713[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象