双板耳板栅对铅酸电池性能的影响  

The effects of bi-lug grid on the performance of lead-acid battery

在线阅读下载全文

作  者:杨滔 黄伟国 唐胜群 陈理 王鹏伟 YANG Tao;HUANG Weiguo;TANG Shengqun;CHEN Li;WANG Pengwei(R&D Centre of Chilwee Power Group Co.,Ltd.,Changxing Zhejiang 313100,China)

机构地区:[1]超威电源集团有限公司研究院,浙江长兴313100

出  处:《蓄电池》2023年第4期151-155,共5页Chinese LABAT Man

基  金:湖州市科技局资助项目(编号2022GG42)。

摘  要:比较了双板耳板栅/极板与常规单极耳板栅/极板的各种性能。与常规板栅相比,双板耳板栅上不同部位的电阻差值下降0.32 mΩ。放电末期双极耳极板上电流密度、电位分布,以及活性物质利用率都比常规极板更加均匀。最后,测试了分别采用这2种板栅的电池的低温起动性能和大电流放电性能。测试结果表明,采用双极耳板栅的电池的低温起动性能和大电流放电性能更好。The performance of bi-lug grid/plate was compared with that of conventional grid/plate with single lug.Compared with the conventional single lug grid,The difference of resistance in different parts of the grid of the bi-lug grid decreased by 0.32 mΩ.At the end of discharge,the current density,potential distribution and active substance utilization ratio of the bi-lug plate are more uniform than those of the conventional single lug plate.Finally,the low temperature starting performance and high current discharge performance of the cells using these two kinds of grids were compared.The test results show that the low temperature starting performance and high current discharge performance of the battery with bi-lug grid are better.

关 键 词:铅酸蓄电池 双板耳 板栅 电阻分布 电流密度 电位 活性物质利用率 大电流放电 低温起动性能 

分 类 号:TM912.1[电气工程—电力电子与电力传动]

 