检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Jingtian Bi Huadong Sun Shiyun Xu Ruihua Song Bing Zhao Qiang Guo
出 处:《CSEE Journal of Power and Energy Systems》2023年第4期1337-1347,共11页中国电机工程学会电力与能源系统学报(英文)
基 金:supported in part by the National Natural Science Foundation of China under Grant No.U1766202,51907179 and 51977197.
摘 要:The mode-based damping torque analysis(M-DTA)method for studying the effect of an external controller on power system low-frequency oscillations is proposed in this paper.First,based on the interconnection model between the system and the controller in the frequency domain,the oscillation loop corresponding to the electromechanical oscillation mode is built,and then the mode-based damping torque of the controller can be calculated.Then,the application of the M-DTA method in the power system is illustrated.The derivation shows that in the single-machine infinite-bus power system,the M-DTA method is completely equivalent to the classical damping torque analysis(C-DTA)method.In the multi-machine power system,the mode-based damping torque directily reflects the effect of the controller on the oscillation mode,overcoming the shortcomings of the C-DTA method in which there is no direct correspondence between the damping torque and the oscillation mode.By deriving the relationship with the residue index,the M-DTA method shows higher accuracy than the residue method in applications,such as controller parameter adjustment.Finally,two example power systems are presented to demonstrate the application of the proposed M-DTA method.Index Terms-Electromechanical oscillation mode,FACTS,interconnection model in the frequency domain,mode-based damping torque analysis(M-DTA),power system low-frequency oscillation,PSS,residue method.
关 键 词:Electromechanical oscillation mode FACTS interconnection model in the frequency domain mode-based damping torque analysis(M-DTA) power system low-frequency oscillation PSS residue method.
分 类 号:TM712[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222