检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘宇健[1] 李晓帆[1] 林绮文[1] 陈大伟[1] 冯凡凡 钟慧斌 张文春[1] 聂咏梅[1] LIU Yujian;LI Xiaofan;LIN Qiwen;CHEN Dawei;FENG Fanfan;ZHONG Huibin;ZHANG Wenchun;NIE Yongmei(Guangzhou Blood Center,Guang zhou 510095,China)
机构地区:[1]广州血液中心,广东广州510095
出 处:《中国输血杂志》2023年第8期728-731,共4页Chinese Journal of Blood Transfusion
基 金:广东省医学科学技术研究基金项目(B2021251);市校(院)联合资助专题(市卫生健康委员会基础与应用基础研究项目2023A03J0544)。
摘 要:目的探讨血小板捐献者自身凝血状态对机器采集的血小板体外聚集现象是否有影响。方法设血小板体外聚集实验组(简称实验组):选择既往以AMICUS血细胞分离机采集单采血小板并曾发生血小板体外聚集现象≥3次,且最后1次发生在其最近1次捐献单采血小板时的献血者30名作为研究对象;对照组:选择既往以AMICUS血细胞分离机采集单采血小板数≥3次并从未发生血小板体外聚集现象的献血者30名作为研究对象。实验开始(此次单采血小板)前,2组对象均使用全自动血液细胞分析仪(BC-3000Plus)检测外周血Plt、MPV、PDW、Pct、P-LCR等血小板基本参数,使用血栓弹力图(TEG)仪检测凝血反应时间(R)、凝血形成时间(K)、凝血速率(α)、最大血凝块强度(MA)、凝血指数(CI)等TEG参数。应用SPSS24.0统计软件,采用t检验分析比较2组检测参数的差异。结果实验与对照组除CI为0.48±1.00 vs-0.99±1.96(P<0.05)外,所有血小板基本参数及其他TEG参数比较无明显差异(P>0.05)。结论献血者自身凝血状态可能是引发其单采血小板出现体外聚集现象的独立风险因素。Objective To investigate whether the blood donors’coagulation status may lead to apheresis platelet aggregation in vitro.Methods Thirty blood donors with aggregation in apheresis platelets collected by AMICUS blood cell separator no less than 3 times previously and occurred when the last time of apheresis donation were observed in aggregated group(referred to as the experimental group);Thirty donors without aggregation in apheresis platelets collected by AMICUS blood cell separator no less than 3 times were observed in the control group simultaneously.The basic platelet parameters in the two groups,including Plt,MPV,PDW,Pct,P-LCR were detected by automatic blood cell analyzer(BC-3000Plus),and thromboelastogram indexes including reaction time(R),kinetics time(K),kinetics of clot development(α),maximum amplitude(MA)and coagulation index(CI)were tested by Thrombosis elastography(TEG)before collection.With SPSS24.0 software,t test was used to compare the differences between the two groups.Results The CI value in experimental group was significantly different from that of the control group(0.48±1.00 vs-0.99±1.96,P<0.05),and there was no significant difference in all above basic platelet parameters and other TEG parameters(P>0.05).Conclusion The coagulation status of blood donors may be an independent risk factor for the in vitro aggregation of apheresis platelets.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.33