摘 要:为解决供用电系统和用电设备的正常漏电电流与故障漏电电流的保护和识别问题,首先针对供用电系统和用电设备的漏电特征进行分析,明确正常漏电与故障漏电的识别特征;其次分析高频电力电子设备的漏电电流特征,提出基于高频电流负反馈的磁调制漏电电流量测方法,实现故障漏电的准确检测与保护;最后提出基于漏电电流阻容特征的单相供用电系统的漏电保护策略,分别设置故障漏电动作阈值和正常漏电动作阈值,在保障供用电系统和用电设备正常运行的前提下实现故障漏电的准确保护。结果表明:正常漏电与故障漏电电流阻容特征不同;基于高频电流负反馈的磁调制漏电电流量测方法可以有效降低正常高频容性漏电电流的影响;基于漏电电流的阻容特征的漏电保护策略,可提高漏电保护的有效性和可靠性。In order to solve the protection and identification of normal leakage current and fault leakage current of power supply and consumption system and electrical equipment,firstly,the leakage characteristics of power supply and consumption system and electrical equipment are analyzed.Identify the identification characteristics of normal leakage and fault leakage;secondly,the leakage current characteristics of high-frequency power electronic equipment are analyzed.A magnetic modulation leakage current measurement method based on high frequency current negative feedback is proposed to realize the accurate detection and protection of fault leakage;finally,the leakage protection strategy of single-phase power supply and consumption system based on the characteristics of leakage current resistance and capacitance is proposed.Set the fault leakage action threshold and normal leakage action threshold respectively,on the premise of ensuring the normal operation of power supply and consumption system and electrical equipment,the accurate protection of fault leakage is realized.The results show that the characteristics of normal leakage current and fault leakage current are different;the magnetic modulation leakage current measurement method based on the negative feed-back of high-frequency current can effectively reduce the influence of normal high-frequency capacitive leakage current;the leakage protection strategy based on the resistance capacitance characteristics of leakage current can improve the effectiveness and reliability of leakage protection.
关 键 词:分布式阻抗 阻性漏电 容性漏电 电流测量 故障漏电保护
分 类 号:TM930.1[电气工程—电力电子与电力传动]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.63