检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:周灿辉 杨萧帆 张宏宇 张宗劲 李笛[3] 李淑更[3] 张立秋[2] ZHOU Canhui;YANG Xiaofan;ZHANG Hongyu;ZHANG Zongjin;LI Di;LI Shugeng;ZHANG Liqiu(Jiangmen Yamen New Fortune Environmental Protection Industry Co.,Ltd.,Jiangmen 529152,China;School of Civil Engineering,Guangzhou University,Guangzhou 510006,China;School of Environmental Science and Engineering,Guangzhou University,Guangzhou 510006,China)
机构地区:[1]江门市崖门新财富环保工业有限公司,广东江门529152 [2]广州大学土木工程学院,广东广州510006 [3]广州大学环境科学与工程学院,广东广州510006
出 处:《工业水处理》2023年第8期143-148,共6页Industrial Water Treatment
基 金:广州市科技计划项目(202102010396)。
摘 要:针对电镀废水中因含有硫脲类物质而造成生物处理系统硝化受抑制的问题,以广东省某电镀废水厂为例,通过硫脲对硝化的抑制原理、铜离子与硫脲对硝化抑制与恢复特性试验及电镀废水生物处理系统长期项目运行数据分析,得出电镀废水生物处理系统运行中次氯酸钠投加、铜离子浓度与硫脲相互作用是导致硝化抑制与恢复的原因。铜离子与硫脲形成配合物后不再对氨氧化菌产生抑制,而次氯酸钠可解除硫脲与铜离子的配合态,使硫脲对氨氧化菌重新获得抑制性。小试研究发现0.2、0.5、1.0 mg/L的硫脲对氨氧化菌分别造成59.5%、82.5%、100.6%的硝化抑制率,并通过Cu(Ⅱ)与硫脲的抑制恢复试验得出0.5、2.0、5.0 mg/L Cu(Ⅱ)在1.0 mg/L硫脲抑制条件下氨氧化菌的硝化速率恢复率分别为13.1%、42.6%、104.4%。试验结论对含有硫脲类电镀废水的生物硝化处理提供借鉴和解决了生物脱氮稳定性的难题。There exists the problem of inhibition of nitrification system caused by thiourea in electroplating wastewa⁃ter.Taking an electroplating wastewater plant in Guangdong province as an example,through the inhibition prin⁃ciple of thiourea on nitrification,the inhibition and recovery characteristics test of copper ion and thiourea on nitrifi⁃cation,and the analysis of long-term project operation data of electroplating wastewater biochemical treatment sys⁃tem were carried out.It was concluded that the addition of sodium hypochlorite and the interaction between copper ion concentration and thiourea resulted in the inhibition and recovery of nitrification in the operation of electroplat⁃ing wastewater biochemical treatment system.After the copper ion and thiourea formed the complex,they no longer inhibited the ammonia-oxidizing bacteria.However,sodium hypochlorite could remove the coordination state of thio⁃urea and copper ion and make thiourea regain inhibition to the ammonia-oxidizing bacteria.An experience showed that 0.2,0.5 and 1.0 mg/L thiourea could inhibit the nitrification of ammonia-oxidizing bacteria by 59.5%,82.5%,and 100.6%,respectively.Through the inhibition and recovery tests of Cu(Ⅱ)and thiourea,it was concluded that the nitrification rate recovery rates of Ammonia-oxidizing bacteria with 0.5,2,and 5 mg/L Cu(Ⅱ)under the inhibi⁃tion of 1.0 mg/L thiourea were 13.1%,42.6%,and 104.4%,respectively.The experimental conclusion can be used for reference for biological nitrification treatment of electroplating wastewater containing thiourea and solve the prob⁃lem of biological denitrification stability.
分 类 号:X703[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.171