检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:何维 谢欢欢 辛拓 张宏钊 陈龙 黄炜昭 HE Wei;XIE Huanhuan;XIN Tuo;ZHANG Hongzhao;CHEN Long;HUANG Weizhao(Shenzhen Power Supply Bureau Co.,Ltd.,Shenzhen,Guangdong 518000,China)
出 处:《自动化与仪器仪表》2023年第7期299-303,共5页Automation & Instrumentation
基 金:深圳供电局有限公司《支撑智能运检的新型变电站及装备模块化技术研究》(090000KK52200150)。
摘 要:针对传统主变压器温度监测仪表故障诊断准确率低的问题,设计一种基于谱峭度与复Morlet小波的主变压器温度监测仪表故障诊断系统。首先,通过采集板中的温度传感器进行主变压器温度和振动数据采集;然后将采集数据传输至处理板,利用谱峭度提取温度监测仪表中的脉冲信号,从而获取复Morlet小波的中心频率和尺度;最后通过复Morlet小波进行信号处理,以此提升温度监测仪表的故障诊断准确率。结果表明,采用谱峭度法进行主变压器内环轴承振动数据提取的中心频率和带宽分别为1.75 kHz和500 Hz,可确定内环轴承故障的谱峭度共振频率为1.5 kHz~2 kHz。设定的内环故障频率为162.2 Hz,采用复Morlet小波进行变换后,在包络频域的163 Hz处出现峰值,找到主变压器温度监测仪表内环轴承的故障。由此说明,本方法可实现温度监测仪表信号的共振频率提取。可有效屏蔽外部噪声干扰,提高主变压器温度监测仪表故障诊断精度。Aiming at the problem of low fault diagnosis accuracy of traditional main transformer temperature monitoring instrument,a fault diagnosis system of main transformer temperature monitoring instrument based on spectral cliff and complex Morlet wavelet is designed.Firstly,the temperature and vibration data of the main transformer are collected by the temperature sensor in the acquisition board;then the collected data is transmitted to the processing board to extract the pulse signal in the temperature monitoring instrument for the center frequency and scale of the complex Morlet wavelet;finally,the signal processing through the complex Morlet wavelet to improve the fault diagnosis accuracy of the temperature monitoring instrument.The results show that the center frequency and bandwidth of the vibration data are 1.75 kHz and 500Hz respectively,and the resonance frequency of the inner ring bearing is 1.5~2 kHz.The set internal ring fault frequency is 162.2Hz.After transforming with complex Morlet wavelet,the peak occurs at 163Hz in the envelope frequency domain,and the fault of the inner ring bearing of the main transformer temperature monitoring instrument is found.This result shows that the present method can realize the resonance frequency extraction of the temperature monitoring instrument signal.It can effectively shield the external noise interference and improve the fault diagnosis accuracy of the main transformer temperature monitoring instrument.
关 键 词:复Morlet小波 主变压器 温度监测仪表 谱峭度 故障诊断
分 类 号:TP392[自动化与计算机技术—计算机应用技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.38