尿素装置入口管道泄漏原因  被引量:2

Leakage cause of inlet pipeline of urea units

在线阅读下载全文

作  者:谭川江[1] 张金星[1] 侯永宾[1] 武飞 陈百龄 TAN Chuanjiang;ZHANG Jinxing;HOU Yongbin;WU Fei;CHEN Bailing(PetroChina Tarim Oilfield Company,Korla 841000,China)

机构地区:[1]中国石油塔里木油田分公司,库尔勒841000

出  处:《理化检验(物理分册)》2023年第6期59-62,共4页Physical Testing and Chemical Analysis(Part A:Physical Testing)

摘  要:某公司尿素装置蒸发系统入口管道在服役过程中发生泄漏,采用宏观观察、渗透检测、化学成分分析、金相检验、扫描电镜和能谱分析等方法分析了其泄漏原因。结果表明:管外壁保温层中含氯离子,雨水的浸湿使管壁与导热泥的缝隙中形成了潮湿环境,干湿交替环境导致氯离子在管壁富集,引起管壁点腐蚀和氯化物应力腐蚀开裂。Leakage occurred in the inlet pipeline of the evaporation system of a urea units during service.The cause of leakage was analyzed by means of macroscopic observation,penetrant testing,chemical composition analysis,metallographic examination,scanning electron microscope and energy spectrum analysis.The results show that the insulation layer of the outer wall of the pipe contained chloride ions.Due to the wetting of rainwater,a humid environment was formed in the gap between the pipe wall and the heat conducting mud.The dry-wet alternating environment led to the enrichment of chloride ions in the pipe wall,caused pitting corrosion and chloride stress corrosion cracking.

关 键 词:管道 点腐蚀 应力腐蚀开裂 泄漏 

分 类 号:TB31[一般工业技术—材料科学与工程] TB304[金属学及工艺—物理冶金] TG115.2[金属学及工艺—金属学]

 