混合结构体系旧厂房的分缝隔震组合加固技术  被引量:1

Split-seam Seismic lsolation Combined Reinforcement Technology for Old Factory Buildings with Mixed Structure System

在线阅读下载全文

作  者:尹伟 顾夏英 YIN Wei;GU Xiaying(Suzhou Zhonggu Building Science and Technology Co.,Ltd.,Suzhou 215000,Jiangsu,China)

机构地区:[1]苏州中固建筑科技股份有限公司,江苏苏州215000

出  处:《建筑施工》2023年第8期1580-1583,共4页Building Construction

摘  要:结合工程实际,对采用1989年及以前版抗震规范建成的框架和砌体混合承重体系房屋,在抗震能力不足方面的问题,提出了采用对结构整体切割设置抗震缝,对框架部分采用隔震方式进行加固的方法。针对独立基础底部配筋不满足最小配筋率,提出了一种刚性基础的加固方式,可为类似项目提供借鉴。Based on engineering practice,a method of cutting and setting seismic joints on the entire structure and strengthening the frame part through isolation is proposed to address the issue of insufficient seismic capacity of frame and masonry hybrid load-bearing system buildings built using the year 1989 and previous seismic specifications.A reinforcement method for rigid foundations is proposed to address the issue that the bottom reinforcement of independent foundations does not meet the minimum reinforcement ratio,which can provide reference for similar projects.

关 键 词:混合结构建筑 分缝隔震组合加固 独立基础 刚性加固 

分 类 号:TU758[建筑科学—建筑技术科学]

 