通信阀控铅酸蓄电池维护的问题与对策  被引量:1

Maintenance Problems and Countermeasures of Communication VRLAB

在线阅读下载全文

作  者:沈玉田 赵晨 陈熙平 李洪涛 廖程远 廖晋伟 SHEN Yu-tian;ZHAO Chen;CHEN Xi-ping;LI Hong-tao;LIAO Cheng-yuan;LIAO Jin-wei(Yalong River Hydropower Development Company.Ltd.,Jinping Hydropower Plant,Xichang 615000,China)

机构地区:[1]雅砻江流域水电开发有限公司锦屏水力发电厂,四川西昌615000

出  处:《云南水力发电》2023年第9期269-271,共3页Yunnan Water Power

摘  要:加强对电厂通信阀控铅酸蓄电池维护和管理的研究,有利于提高通信蓄电池的维护和管理水平,具有重要的现实意义。针对在通信蓄电池维护工作中出现的各类安全和技术问题,提出通信蓄电池维护的具体措施,总结一套完整可靠的运维管理经验,对提高厂内通信系统安全运行水平具有重大意义。Strengthening the research on the maintenance and management of communication VRLAB in power plants is conducive to improving the maintenance and management level of communication batteries,which has important practical significance.In response to various safety and technical issues that arise in the maintenance of communication batteries,this paper proposes specific measures for communication battery maintenance and summarizes a complete and reliable set of operation and management experience,which is of great significance for improving the safe operation level of the communication system in the factory.

关 键 词:通信蓄电池 阀控铅酸蓄电池 充放电试验 过渡板 I10放电率 

分 类 号:TV734[水利工程—水利水电工程] TV738

 