作 者:林信坤 LIN Xinkun(Fujian Jiangong Prefabricated Research Institute Co.,Ltd.,Fuzhou 350001,China)
机构地区:[1]福建建工装配式建筑研究院有限公司,福州市350001
出 处:《建筑电气》2023年第8期16-20,共5页Building Electricity
摘 要:根据低压配电线路短路保护灵敏度要求,分析提高低压配电线路短路保护灵敏度的主要措施。利用现有国家标准图集19DX101-1《建筑电气常用数据》有关数据,推导出方便快速判定TN接地系统低压配电线路短路保护灵敏度能否满足要求的方法。Based on the sensitivity requirements for short-circuit protection in low-voltage distribution lines,this article analyzes the main measures to improve theshort-circuit protection sensitivityyof low-voltage distribution lines.By utilizing the relevant data from the existing national standard atlas 19DX101-1 Common Data for Building Electrical Systems,a method is derived to conveniently and quickly determine whether the short-circuit protection sensitivity of TN earthing system in low-voltage distribution lines meets the requirements.