基于CPU工作状态进行温度估算的数据中心服务器功耗模型  被引量:2

Data Center Server Power Consumption Model Based on Temperature Estimation Considering CPU Working State

在线阅读下载全文

作  者:朱介北 刘东昊 李炳森 俞露杰 田娜 贾宏杰 ZHU Jiebei;LIU Donghao;LI Bingsen;YU Lujie;TIAN Na;JIA Hongjie(School of Electrical and Information Engineering,Tianjin University,Tianjin 300072,China;State Grid Information&Telecommunication Group Co.,Ltd.,Beijing 102211,China;Eco-Tech Research Institute of State Grid Hebei Electric Power Co.,Ltd.,Shijiazhuang 300171,China)

机构地区:[1]天津大学电气自动化与信息工程学院,天津市300072 [2]国网信息通信产业集团有限公司,北京市102211 [3]国网河北省电力有限公司经济技术研究院,河北省石家庄市300171

出  处:《电力系统自动化》2023年第14期140-148,共9页Automation of Electric Power Systems

基  金:国家重点研发计划资助项目(2018YFA0702200)。

摘  要:为实现数据中心节能降耗,数据中心服务器功耗模型的精确构建至关重要。传统仅基于CPU利用率的服务器功耗模型,忽略了受温度变量影响的服务器功耗延迟变化动态特性,无法区分在CPU波动或阶跃不同工作状态下的服务器功耗分层现象,导致较大的模型误差。文中提出一种基于CPU工作状态进行温度估算的数据中心服务器功耗模型(PMTC)。PMTC通过在模型建立过程中计及温度变量,捕捉受CPU核心温度延迟变化影响的服务器功耗延迟变化动态特性,消除基于CPU工作状态的服务器功耗分层导致的模型误差;在功耗计算过程中,通过判断CPU工作状态进行CPU核心温度的精确估算,避免了对温度变量的额外测量。通过搭建的功耗测试平台对比了PMTC与传统服务器功耗模型,验证了所提PMTC在不增加额外温度测量设备和输入数据维度的前提下,还原了服务器功耗延迟变化动态特性,显著降低了模型计算误差。To achieve the energy saving in data centers,it is crucial to accurately construct power consumption models for data center servers.The traditional server power consumption model based solely on CPU utilization ignores the dynamic characteristics of server power delay changes influenced by temperature variables,and cannot distinguish the phenomenon of server power layering under different CPU working states of fluctuation or step,resulting in significant model errors.A data center server power consumption model based on temperature estimation considering CPU working state(PMTC)is proposed.PMTC captures the dynamic characteristics of server power consumption delay changes which are affected by CPU core temperature delay changes considering the temperature variables during the model establishment process,eliminates model errors caused by CPU working states based server power consumption layering.During the power consumption calculation process,accurate estimation of the CPU core temperature is performed by judging the CPU working state,avoiding additional measurement of temperature variables.By comparing the PMTC with traditional server power consumption models through the built power consumption testing platform,it is verified that the proposed PMTC restores the dynamic characteristics of server power consumption delay changes without adding additional temperature measurement devices and inputting data dimensions,significantly reducing model calculation errors.

关 键 词:负荷建模 数据中心 服务器 功耗模型 热电耦合 

分 类 号:TP308[自动化与计算机技术—计算机系统结构] TP368.5[自动化与计算机技术—计算机科学与技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象