^(222)Rn calibration procedure for water analyses by liquid scintillation counting  

在线阅读下载全文

作  者:Ana Rita Gomes Sérgio Dias Anabela Mourato Joao Abrantes Mário Reis 

机构地区:[1]Laboratório de Protecao e Seguranca Radiológica,Instituto Superior Técnico,Universidade de Lisboa,Estrada Nacional 10,km 139,7,2695‑066 Bobadela LRS,Portugal [2]Laboratórios de Massa e Massa Volúmica de Sólidos,Instituto Portugues da Qualidade,Rua António Giao,2,2829‑513 Caparica,Portugal [3]Centro de Ciências e Tecnologias Nucleares,Instituto Superior Técnico,Universidade de Lisboa,Estrada Nacional 10,km 139,7,2695‑066 Bobadela LRS,Portugal

出  处:《Radiation Detection Technology and Methods》2023年第2期311-319,共9页辐射探测技术与方法(英文)

基  金:the Fundacao para a Ciencia e Tecnologia(FCT)support through the UID/Multi/04349/2013 project;funding provided by FCTIFCCN(b-on).

摘  要:Purpose Among the several methods to measure ^(222)Rn in water,the liquid scintillation counting(LSC)technique is one of the most sensitive and widely used when analysing non-saline waters by liquid extraction,providing excellent accuracy,precision and low-level detection limits.When using the liquid scintillation counter Tri-Carb 3170 TR/SL(Perkin-Elmer)it is not possible to make an automatic determination of the alpha/beta discrimination parameter,being necessary to evaluate the pulse decay discriminator(PDD)value manually to the ^(222)Rn determination.In this work,we describe the steps to perform the calibration of that type of equipment.Methods The method consists in the preparation of standard samples from a ^(226)Ra certified standard solution and the adjustment of the PDD value by hand until the percentage of alpha events reaches a plateau of a near-constant fraction of total events.The process consists in taking several measures between PDD 80 and 200 with 15 min counting time each.Within the plateau,the alpha/beta ratio was used to determine the plateau final range as well as the optimum PDD value.After that,the calibration standards and blanks were measured and the region of interest(ROI)was established by finding the maximum value for the figure of merit(FOM)in the upper and lower limits.Results The optimal PDD value of 148 was established by the alpha/beta ratio,and after that,it was possible to measure ^(226)Ra standards to perform the calibration.An efficiency of(9.758±0.035)×1^(0-1) was obtained.In routine measurements,a detection limit of about 0.50 Bq L^(-1) is achieved for a 120 min counting time.To evaluate the uncertainty budget,the uncertainties of the net count rate,the efficiency,the sample amount and the decay correction factor were considered.Conclusions A method was developed for the calibration of LSC Tri-Carb 3170 TR/SL with the optimization of the PDD using a ^(226)Ra standard solution.The acquisition to obtain the plot of the variation of the events fraction in each window(alpha an

关 键 词:RADON WATERS Pulse decay discriminator Liquid scintillation counting CALIBRATION 

分 类 号:TL81[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象