A new imaging mode based on X-ray CT as prior image and sparsely sampled projections for rapid clinical proton CT  被引量:1

在线阅读下载全文

作  者:Yu-Qing Yang Wen-Cheng Fang Xiao-Xia Huang Qiang Du Ming Li Jian Zheng Zhen-Tang Zhao 

机构地区:[1]Shanghai Institute of Applied Physics,Chinese Academy of Sciences,Shanghai 201800,China [2]University of Chinese Academy of Sciences,Beijing 100049,China [3]School of Physical Science and Technology,ShanghaiTech University,Shanghai 201210,China [4]Shanghai Synchrotron Radiation Facility,Shanghai Advanced Research Institute,Chinese Academy of Sciences,Shanghai 201204,China [5]Shanghai Key Laboratory of Cryogenics and Superconducting RF Technology,Shanghai,China [6]Suzhou Institute of Biomedical Engineering and Technology Chinese Academy of Sciences,Suzhou,China

出  处:《Nuclear Science and Techniques》2023年第8期64-74,共11页核技术(英文)

基  金:supported by the Research collaboration on Thailand’s new synchrotron light source facility(SPS-II)(No.ANSO-CR-KP-2020-16).

摘  要:Proton computed tomography(CT)has a distinct practical significance in clinical applications.It eliminates 3–5%errors caused by the transformation of Hounsfield unit(HU)to relative stopping power(RSP)values when using X-ray CT for positioning and treatment planning systems(TPSs).Following the development of FLASH proton therapy,there are increased requirements for accurate and rapid positioning in TPSs.Thus,a new rapid proton CT imaging mode is proposed based on sparsely sampled projections.The proton beam was boosted to 350 MeV by a compact proton linear accelerator(LINAC).In this study,the comparisons of the proton scattering with the energy of 350 MeV and 230 MeV are conducted based on GEANT4 simulations.As the sparsely sampled information associated with beam acquisitions at 12 angles is not enough for reconstruction,X-ray CT is used as a prior image.The RSP map generated by converting the X-ray CT was constructed based on Monte Carlo simulations.Considering the estimation of the most likely path(MLP),the prior image-constrained compressed sensing(PICCS)algorithm is used to reconstruct images from two different phantoms using sparse proton projections of 350 MeV parallel proton beam.The results show that it is feasible to realize the proton image reconstruction with the rapid proton CT imaging proposed in this paper.It can produce RSP maps with much higher accuracy for TPSs and fast positioning to achieve ultra-fast imaging for real-time image-guided radiotherapy(IGRT)in clinical proton therapy applications.

关 键 词:Proton CT Real-time image guidance Image reconstruction Proton therapy 

分 类 号:R812[医药卫生—放射医学] TP391.41[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象