作 者:潘慢慢 李杭[2] 徐一仟 杨其穆 蒋丹丹[2] 王卫国[2] 陈创[2,3] 李海洋 PAN Manman;LI Hang;XU Yiqian;YANG Qimu;JIANG Dandan;WANG Weiguo;CHEN Chuang;LI Haiyang(University of Chinese Academy of Sciences,Beijing 100049,China;Dalian Institute of Chemical Physics,Chinese Academy of Sciences,Dalian 116023,Liaoning China;State Key Laboratory of NBC Protection for Civilian,Beijing 102205,China)
机构地区:[1]中国科学院大学,北京100049 [2]中国科学院大连化学物理研究所,辽宁大连116023 [3]国民核生化灾害防护国家重点实验室,北京102205
出 处:《分析测试技术与仪器》2023年第3期231-244,共14页Analysis and Testing Technology and Instruments
基 金:国家自然科学基金项目(Nos.22027804,21974141);国民核生化灾害防护国家重点实验室科研基金项目(SKLNBC2021-16);大连化物所创新研究基金项目(DICP I202141)。
摘 要:离子迁移谱(ion mobility spectrometry,IMS)是利用离子迁移率K(离子碰撞截面)差异来实现不同离子的分离与测定,具有分析速度快、检测灵敏度高的优点,其与质谱联用在蛋白质组学、代谢组学、医药等领域已获得了广泛的应用.随着分析对象复杂性的增加,对IMS的分辨能力也提出了更高要求.行波离子迁移谱(travelling wave ion mobility spectrometry,TWIMS)采用时域连续的行波电场实现离子传输与分离,其分析通道的长度不受行波电压幅值的限制,理论上可以无限延长离子分析通道来提高分辨能力.目前,TWIMS的分辨率最高可达1860,对于分析存在多种同分异构体的复杂样品别具优势.对TWIMS的原理及分辨能力的影响因素进行了介绍,进一步探讨了不同结构TWIMS仪器的特点、性能和应用,对TWIMS未来发展方向进行了展望.Ion mobility spectrometry(IMS)utilizes the difference in ion mobility K(collision cross section)to realize the separation and determination of different ions,which has the advantages of fast analysis speed and high sensitivity.And it coupling with mass spectrometry(IM-MS)was widely used in the fields of proteomics,metabolomics,medicine,etc.With the increasing complexity of the analyzed objects,higher demands are put on the resolution of the IMS.Traveling wave ion mobility spectrometry(TWIMS)uses a time-domain continuous traveling wave electric field to realize ion transport and separation.The analytical path length of the TWIMS is not limited by the amplitude of the travelling wave voltage,theoretically the path can be extended indefinitely to improve the resolution.Currently,the resolution of TWIMS can reach up to 1860,which is advantageous for the analysis of complex samples with the multiple isomers.The principle of TWIMS and the influencing factors of resolution were introduced,the characteristics,performance and applications of TWIMS instruments with different structures were further discussed,and finally the future development directions of TWIMS were prospected.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.119.131.131