火焰原子吸收法测定陶瓷制品中铅和镉的溶出量  被引量:1

Determination of Dissolved Lead and Cadmium in Ceramic Products by Flame Atomic Absorption Spectrometry

在线阅读下载全文

作  者:于文斌 张璐璐 张茹月 何丰翼 YU Wen-bin;ZHANG Lu-lu;ZHANG Ru-yue;HE Feng-yi(Nantong Center for Disease Control and Prevention,Nantong Jiangsu 226000,China)

机构地区:[1]南通市疾病预防控制中心,江苏南通226000

出  处:《辽宁化工》2023年第9期1392-1395,共4页Liaoning Chemical Industry

摘  要:建立了火焰原子吸收法测定食品接触用陶瓷制品中铅、镉溶出量的测定方法。结果表明,相关系数均大于0.999,铅、镉的方法检出限分别为0.07、0.007 mg/L,加标回收率分别为97.83%和94.91%,相对标准偏差分别为1.06%、2.94%。同时对比分析了不同乙酸溶液浓度、浸泡时间和浸泡温度对陶瓷制品铅、镉溶出量的影响,确定最优条件为使用4%浓度乙酸在22℃条件下浸泡24 h。该方法简便高效,精密度好,准确度高,可用于日用陶瓷制品中铅、镉溶出量测定。A method for the determination of lead and cadmium in ceramic products for food contact by flame atomic absorption spectrometry was established.The results showed that the correlation coefficients were greater than 0.999.The detection limits of lead and cadmium were 0.07 mg·L-1 and 0.007 mg·L-1,respectively.The recoveries were 97.83%and 94.91%,respectively.The relative standard deviations were 1.06%and 2.94%,respectively.At the same time,the effects of different acetic acid solution concentration,soaking time and soaking temperature on the dissolution of lead and cadmium in ceramic products were compared and analyzed.The optimum conditions were determined to be soaking for 24 h with 4%acetic acid at 22℃.The method is simple and efficient,has good precision and high accuracy,and can be used for the determination of lead and cadmium dissolution in daily ceramic products.

关 键 词:火焰原子吸收法 陶瓷 铅和镉 溶出量 

分 类 号:O657.31[理学—分析化学]

 