检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:盛有 郝庆妮 SHENG You;HAO Qingni
出 处:《电力系统装备》2023年第8期87-89,共3页Electric Power System Equipment
摘 要:在10 kV高压配电网运行过程中,线损计算与降损工作是确保电力系统安全稳定运行的重要工作步骤。当配电网的线损程度超过一定阈值时,会导致供电质量下降、电能浪费增加、供电可靠性减弱等问题。为此,电力技术人员需要利用科学有效的线损计算方法,进一步分析线损原因,并提出降损措施。因此,文章以10 kV配电网为研究对象,提出一种全新的配电线损计算方法,深入分析10 kV配电网线损原因,并提出相应的降损措施,以期能为该领域的工作人员提供一些可行性参考。During the operation of 10kV high-voltage distribution network,line loss calculation and reduction work are important steps to ensure the safe and stable operation of the power system.When the degree of line loss in the distribution network exceeds a certain threshold,it can lead to problems such as decreased power supply quality,increased energy waste,and weakened power supply reliability.Therefore,power technicians need to use scientific and effective line loss calculation methods to further analyze the causes of line loss and propose loss reduction measures.Therefore,the article takes 10kV distribution network as the research object,proposes a new method for calculating distribution line loss,deeply analyzes the causes of 10kV distribution network line loss,and proposes corresponding loss reduction measures,in order to provide some feasible references for workers in this field.
分 类 号:TM73[电气工程—电力系统及自动化]