检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Bangben Yao Yun Li Ru Zhang Li Yao Jianguo Xu Chao Yan Wei Chen
机构地区:[1]Anui Province Inustinute of Prodtuct Quality Supenvision&Inspection,Hefei 230051,China [2]Engineering Reseanch Center of Bio-Proess,MOE,School of Food cand Biological Engineerng,Hefei University of Techmology,Hefei 230009,China [3]School of Ijfe Science,Anhui University,Hefei 230601,China
出 处:《Journal of Future Foods》2024年第1期97-104,共8页未来食品学报(英文)
基 金:This work was supported by the Postdoctoral Science Foundation of Anhui Province(2020B412),the project of Science and Technology Program of State Administration for Market Regulation(2020MK049);the project of Science and Technology Program of Administration for Market Regulation of Anhui Province(2019MK037).
摘 要:A sensitive and reliable method was developed and validated for the simu1taneous determination of 6 carbamate pesticides and relevant metabolites based on the modified fast QuEChERS(quick,easy,cheap,effective,rugged and safe)method combined with ultra-performance 1iquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The method was also applied in the analysis of 23 commonly consumed oilseeds and oil samples.The sample was extracted with acetonitrile for three times and then the extracted solution was filtered directly though 250 mg precipitated silica adsorbent(PSA)and 250 mg Cis The mobile phase was water(containing 0.1%formic acid)and acetonitrile.The extemal standard protocols were adopted to validate the method in terms of recovery,1inearity,precision,sensitivity,and relative standard deviation(RSD)under the optimized conditions.The linear calibration curves with different ranges were established with R^(2)>0.9973,limit of detections(LODs)ranged from 0.100μg/kg to 20000μg/kg and limit of quantitations(LOQs)ranged from 0.300μg/kg to 6.000μg/kg.The LODs meets the detection requirement for the maximum residue limits in practical samples.Meanwhile,the recoveries ranged from 60.2%to 116.6%with associated RSDs ranged from 0.33%to 5.35%in 10 oilseeds matrices and ranged from 61.9%to 116.9%with RSDs ranged from 0.30%to 5.02%in 13 oil matrices.These features do make the UPLC-MSMS an ideal analytical platform for accurate and high throughput analysis of carbamates residues in the complex matrix.
关 键 词:Carbamate pesticides Oiseeds and oil Dispersive solid-phase extraction U1tra-performance 1iquid chromatography-tandem mass spectometry Simu1taneous determination High throughput
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49