作 者:周毅 李一晨 傅幼书 秦康平 朱文 范栋琦 ZHOU Yi;LI Yichen;FU Youshu;QIN Kangping;ZHU Wen;FAN Dongqi(East China Branch of State Grid Corporation of China,Shanghai 200120,China;College of Automation&College of Artificial Intelligence,Nanjing University of Posts and Telecommunications,Nanjing 210023,China;NARI Technology Development Co.,Ltd.,Nanjing 211106,China)
机构地区:[1]国家电网有限公司华东分部,上海200120 [2]南京邮电大学自动化学院、人工智能学院,南京210023 [3]国电南瑞科技股份有限公司,南京211106
出 处:《哈尔滨理工大学学报》2023年第3期56-66,共11页Journal of Harbin University of Science and Technology
基 金:国家自然科学基金(62073173);江苏省自然科学基金(BK20191376)。
摘 要:电网结构的日益复杂使得电网应对各种事故的能力亟待提高,合理的增加电网备用容量有助于降低电网运行风险。首先考虑极端情况下电网中存在备用不足的风险,将新能源调频、直流调制以及可中断负荷归为电网弹性备用,对其备用潜力进行量化建模。其次,以系统运行总费用最小为目标函数建立计及弹性备用的机组组合优化模型,在Lingo环境下编写优化算法程序,对多种备用资源进行优化。最后,在IEEE-39节点系统中进行算例分析。结果表明,所建模型在保证系统安全的情况下,对日前机组计划进行了重新分配,可以实现资源最优分配,有效缓解常规备用压力,保证系统稳定运行。The increasing complexity of the grid structure makes the grid′s ability to respond to various accidents urgently need to be improved,and a reasonable increase in grid reserve capacity can help reduce grid operation risks.Under extreme conditions of the power grid,the risk of insufficient reserve is considered in this article.New energy frequency modulation,DC modulation and interruptible load are classified as grid flexible reserve,and the reserve potential is quantified.Secondly,a unit combination model considering the flexible reserve is established with the objective function of minimizing the total operating cost of the system,and the optimization algorithm program is written in the Lingo environment to optimize a variety of reserve resources.Finally,an example is analyzed in IEEE 39-bus system.The results show that the built model redistributes the day-ahead unit plan under the condition of ensuring the safety of the system,which can realize the optimal allocation of resources,effectively alleviate the pressure of conventional reserve,and ensure the stable operation of the system.
分 类 号:TM712[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222