基于Midas/FEA模型的预制混凝土墙板加固砌体模拟分析  

Simulation Analysis of Masonry Strengthened with Precast Concrete Wall Panels Based on Midas/FEA Model

在线阅读下载全文

作  者:薛海朋 李佳[1] 李向宇 XUE Hai-peng;LI Jia;LI Xiang-yu(Hebei Jianyan Technology Co,Ltd,Shijiazhuang 050000,China;Hebei Xinyuan Construction Engineering Testing Co,Ltd,Shijiazhuang 050000,China)

机构地区:[1]河北建研科技有限公司,石家庄050000 [2]河北新源建筑工程检测有限公司,石家庄050000

出  处:《建材世界》2023年第5期98-104,共7页The World of Building Materials

摘  要:采用预制钢筋混凝土墙板加固砌体可以有效提高砌体结构抗震性能。采用传统现浇钢筋混凝土面层和预制钢筋混凝土墙板构件对1∶2全缩尺素砌体墙进行单面加固试验。文中主要通过Midas FEA非线性有限元软件对素砌体墙、现浇面层加固砌体、预制构件加固砌体进行数值模拟分析,结果表明:两种加固方式加固效果相当;采用预制混凝土构件加固砌体,可以有效提高砌体抗震性能,极限承载力提高6.25倍,最大位移降低约10倍。Strengthening masonry with prefabricated reinforced concrete wall panels can effectively improve the seismic performance of masonry structures.A single side reinforcement test was conducted on a 1∶2 full scale plain masonry wall using traditional cast-in-place reinforced concrete surface layer and prefabricated reinforced concrete wall panel components.The article mainly uses Midas FEA nonlinear finite element software to conduct numerical simulation analysis on plain masonry walls,reinforced masonry with cast-in-place surface layers,and reinforced masonry with prefabricated components.The research results show that the reinforcement effects of the two reinforcement methods are equivalent.Strengthening masonry with prefabricated concrete components can effectively improve its seismic performance,increase its ultimate bearing capacity by 6.25 times,and reduce its maximum displacement by about 10 times.

关 键 词:砌体加固 预制构件 现浇面层 非线性数值分析 

分 类 号:TU756.45[建筑科学—建筑技术科学] TU364

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象