检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:焦良珍[1] 段秀松 邵斌 刘磊 刘腊美[1] 刘冬华[1] JIAO Liangzhen;DUAN Xiusong;SHAO Bin;LIU Lei;LIU Lamei;LIU Donghua(School of Urban Construction,Wuhan University of Science and Technology,Wuhan 430065,China;Wuhan Chengtou Shangfu Real Estate Co.,Ltd.,Wuhan 430416,China)
机构地区:[1]武汉科技大学城市建设学院,武汉430065 [2]武汉城投上府置业有限公司,武汉430416
出 处:《建筑节能(中英文)》2023年第9期42-47,共6页Building Energy Efficiency
基 金:省级大学生创新创业训练计划项目:“大空间纤维织物风管送风特性研究”(S202010488015)。
摘 要:医药仓库对环境条件要求较高,柔性空气分布系统因纤维材质的渗透性和孔口送风的均匀性使其应用广泛。为了研究柔性空气分布系统应用于医药仓库的气流组织特性,为工程设计和实际应用提供指导,用ICEM CFD软件建立柔性空气分布系统物理模型,用FLUENT软件对3种孔口角度和两种货架摆放方式下仓库内温度和速度的分布情况进行模拟及实验验证。结果显示,实验值与模拟值吻合度在92%以上;在柔性风管系统风量一定时,货架横向摆放方式要优于竖向摆放方式,柔性风管送风孔口角度30°优于0°和60°,仓库内温度场更均匀,气流速度波动更小。建议工程中采用30°角送风孔口。Pharmaceutical warehouses have high requirements for environmental conditions.Flexible air distribution systems are widely used because of the permeability of fiber materials and the way of orifice air supply in order to study the air distribution characteristics of the flexible air distribution system applied in the pharmaceutical warehouse,and provide guidance for engineering design and practical application.ICEM CFD software is used to establish the physical model of flexible air distribution system,and FLUENT software is used to simulate and verify the distribution of temperature and velocity in the warehouse under three orifice angles and two shelf placement modes.The results show that the agreement between the experimental value and the simulated value is more than 92%;When the air volume of the flexible air duct system is fixed,the horizontal placement of the rack is better than the vertical placement.The angle of the air supply orifice of the flexible air duct is 30 better than O°and 60°.When the horizontal placement of the rack and the angle of the air supply orifice are 30°,the temperature in the warehouse is more uniform and the speed fluctuation is smaller.The suitable orifice angle of the air duct to the engineering is 30°.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.249