检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨晓波 郭炼 李映月 谭军 YANG Xiaobo;GUO Lian;LI Yingyue;TAN Jun(Chongqing Chuanyi Instrument No.17 Factory Co,.Ltd,.Chongqing 400707,China;Chongqing Chuanyi Automation Co,.Ltd,.Chongqing 400700,China)
机构地区:[1]重庆川仪十七厂有限公司,重庆400707 [2]重庆川仪自动化股份有限公司,重庆400700
出 处:《自动化仪表》2023年第S01期308-311,共4页Process Automation Instrumentation
摘 要:接触式表面温度测量所用仪表因结构简单、经济性好,被广泛应用在各种工业领域。但其测量的复杂性和测量结果的不确定性,在实际工程应用中研究得还不够充分,使用中引起的测量准确性问题也频繁出现。为此,有必要对壁温测量中影响准确性的因素进行研究,从而为工程应用提供参考。对钢制管道表面温度测量的特点、测量准确性误差来源、表面温度计类型的选择以及表面温度测点设置进行论证和分析,并在分析的基础上开展了多类型温度计不同安装方式的对比验证试验。验证结果表明在壁温测量应用中,相同结构和材质的热电偶温度计的动态响应性能和测温准确性优于铂热电阻;同类型、相同结构和材质的温度计捆绑式或焊接式安装的测温准确性高于压力接触式。Instruments used for contact surface temperature measurement are widely used in various industrial fields because of their simple structure and good economy.However,the complexity of its measurement and the uncertainty of the measurement results have not been sufficiently studied in practical engineering applications,and the problems of measurement accuracy caused by its use appear frequently.For this reason,it is necessary to study the factors affecting accuracy in wall temperature measurement,to provide reference for engineering applications.The characteristics of surface temperature measurement of steel pipelines,the sources of measurement accuracy errors,the selection of surface thermometer types and surface temperature measurement point settings are demonstrated and analyzed,and based on the analysis,a comparative validation test is carried out for different installation methods of multiple types of thermometers.Validation results show that,in the wall temperature measurement applications,with the same structure and material thermocouple thermometer dynamic response performance and temperature measurement accuracy is better than platinum resistance temperature detector;with the same type,the same structure,temperature measurement accuracy of material thermometer bundled or welded mounting is higher than pressure contact mounting.
关 键 词:核工业 钢制管道 测温误差 表面温度 测温准确性 温度测点 热电偶 铂热电阻
分 类 号:TH811[机械工程—仪器科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.137.161.247