二氧化碳汽提塔列管腐蚀速率高的分析和对策  被引量:1

ANALYSIS AND COUNTERMEASURE OF HIGH CORROSION RATE OF TUBE ARRAY OF CARBON DIOXIDE STRIPPER

在线阅读下载全文

作  者:刘杰 杨应奎 刘建军 Liu Jie;Yang Yingkui;Liu Jianjun(Chongqing Jianfeng Chemical Co.,Ltd.,Chongqing 408017)

机构地区:[1]重庆建峰化工股份有限公司,重庆408017

出  处:《大氮肥》2023年第5期333-336,共4页Large Scale Nitrogenous Fertilizer Industry

摘  要:通过对二氧化碳汽提塔换热列管腐蚀情况的分析研究,判断腐蚀增速原因为高压系统氧含量偏低、氨碳比偏低、系统水碳比偏高、汽提塔加热蒸汽压力偏高、汽提塔列管进料不均等,从工艺条件及设备局部更新两方面采取相应解决措施,减缓了汽提塔列管腐蚀速率,延长了汽提塔使用寿命。Through the analysis and research on the corrosion of heat exchange tube of carbon dioxide stripper,it is concluded that the reasons for the corrosion are low oxygen content in high pressure system,low ammonia carbon ratio,high water carbon ratio,high steam pressure of stripper and unequal feeding of stripper tube.The corrosion rate of stripper tube was reduced and the service life of stripper was prolonged by taking corresponding measures from two aspects of process conditions and partial equipment updating.

关 键 词:汽提塔 换热列管 腐蚀速率 

分 类 号:TQ440.5[化学工程—化学肥料工业]

 