作 者:张子达 杨维芳 姬晓晓 李文辉 ZHANG Zi-da;YANG Wei-fang;JI Xiao-xiao;LI Wen-hui(Faculty of Geomatics,Lanzhou Jiaotong University,Lanzhou,Gansu 730070,China;Nation-Local Joint Engineering Research Center of Technologies and Applications for National Geographic State Monitoring,Lanzhou,Gansu 730070,China;Gansu Provincial Engineering Laboratory for National Geographic State Monitoring,Lanzhou,Gansu 730070,China;Gansu Quality Supervision and Inspection Station for Surveying and Mapping Products,Lanzhou,Gansu 730070,China)
机构地区:[1]兰州交通大学测绘与地理信息学院,甘肃兰州730070 [2]地理国情监测技术应用国家地方联合工程研究中心,甘肃兰州730070 [3]甘肃省地理国情监测工程实验室,甘肃兰州730070 [4]甘肃省测绘产品质量监督检验站,甘肃兰州730070
出 处:《计量学报》2023年第9期1369-1374,共6页Acta Metrologica Sinica
基 金:国家自然科学基金(42061076);国家重点研发计划(2016YFB0501802);兰州交通大学优秀平台(201806)。
摘 要:ISO/IEC 17025要求“开展检测的实验室应评定测量不确定度”,但现行使用的全站仪加常数、乘常数检定流程和检定结果没有不确定度分析和评价,所得检定测量结果缺乏量化参数的描述。以TS06power-2″型号全站仪为例,使用不确定度传递法和蒙特卡罗法对加常数、乘常数测量进行了不确定度评价。研究结果表明,2种评定方法加常数、乘常数的评定结果差值分别为0.04 mm和0.09 mm,且2种评定方法的评定结果都满足检定限差要求,说明2种评定方法均有效且可行。ISO/IEC 17025 requires that“the laboratory carrying out testing shall evaluate the measurement uncertainty”,but the current total station plus constant and multiplication constant verification process and verification results have no uncertainty analysis and evaluation,and the verification and measurement results lack the description of quantitative parameters.Taking TS06power-2″total station as an example,the uncertainty transfer method and Monte Carlo method are used to evaluate the uncertainty of the measurement of addition constant and multiplication constant.The research results indicate that the difference between the two evaluation methods in the evaluation results of additive constant and multiplicative constant are 0.04 mm and 0.09 mm,respectively,and both meet the verification limit requirements,indicating that both evaluation methods are effective and feasible.
关 键 词:计量学 全站仪 不确定度 加常数 乘常数 检定 GUM法 MCM法
分 类 号:TB92[一般工业技术—计量学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49