Mitigation of the impacts of electric vehicle charging on energy-star ratings for residential buildings in India  

在线阅读下载全文

作  者:Rakesh Dalal Devender Kumar Saini 

机构地区:[1]Electrical Cluster,School of Engineering,University of Petroleum and Energy Studies(UPES),Dehradun,India

出  处:《Clean Energy》2023年第5期981-993,共13页清洁能源(英文)

摘  要:The star-labelling programme for residential buildings was introduced by India in 2020 and applies to all residential buildings with no lower limit on the built-up area or electrical demand.The energy-star label for a residential building is awarded against the notified standard by the regulatory body and electric vehicles(EVs)have not been accommodated as a load for residential buildings.The en-ergy consumption of an existing residential building is taken from a study already carried out and compared with the requirement of the Indian residential star-labelling programme with an EV as a plugged-in load.An annual energy gap of 6060 kWh for the existing residential buildings considered in this study for five-star building energy labels increases to 7784 kWh if the EV load is added to the building load.The residential building will lose two energy stars if it caters to the EV load and,to bridge this energy gap,the replace-ment of existing electrical appliances with five-star-rated energy appliances,employing grid-connected rooftop solar photovoltaics(PV)and retrofit of the building envelope are considered.The techno-economic potential of rooftop solar PV and building envelope retrofitting for existing residential buildings is explored using RETScreen®and eQUEST software,respectively.The study establishes that the installation of rooftop solar PV can accommodate the additional load of EVs and can bridge half and three-quarters of the energy gap to achieve five energy stars for an existing building with and without EVs,respectively.It is the most economical option among the options explored in this study.The target Energy Performance Index is achievable by high-end energy consumers(12000 kWh/year)by additional measures,the replacement of inefficient electrical appliances and building envelope retrofitting in addition to the installation of rooftop solar PV.

关 键 词:energy conservation building code energy-star building envelope retrofit EV load 

分 类 号:TM73[电气工程—电力系统及自动化] TP183[自动化与计算机技术—控制理论与控制工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象