作 者:尹林 胡京 王文彬 贺林轩 周恺 苏朝辉 闫磊[5] 刘若溪 王博 屠幼萍[3] YIN Lin;HU Jing;WANG Wenbin;HE Linxuan;ZHOU Kai;SU Zhaohui;YAN Lei;LIU Ruoxi;WANG Bo;TU Youping(Jiangxi Electric Power Company,Nanchang 330096,China;Electric Power Research Institute of Jiangxi Electric Power Company,Nanchang 330096,China;North China Electric Power University,Beijing 102206,China;State Grid Beijing Electric Power Research Institute,Beijing 100040,China;State Grid Beijing Electric Power Company Changping Power Supply Company,Beijing 102299,China)
机构地区:[1]国网江西省电力有限公司,南昌330096 [2]国网江西省电力有限公司电力科学研究院,南昌330096 [3]华北电力大学,北京102206 [4]北京电科院,北京100040 [5]国网北京市电力公司昌平供电公司,北京102299
出 处:《电瓷避雷器》2023年第5期171-177,共7页Insulators and Surge Arresters
基 金:国家自然科学基金资助项目(编号:50577021,50877025);江西电网重大专项(面向输配电线路关键业务环节的无人机智能分析技术研究)。
摘 要:随着红外测量技术的不断进步,对绝缘子状态进行红外热像检测逐步应用于电网的日常巡检中,但测量结果受环境因素影响显著。以输电线路现场运行中瓷绝缘子作为研究对象,分别在不同光照强度、湿度、温度与风速下采集绝缘子的红外图像,研究环境因素对绝缘子红外检测的影响规律。研究结果表明,当采用基于绝缘子串温度曲线的判别方法时,光照强度容易引起零值绝缘子的误判,温度变化对零值绝缘子检测没有影响;湿度变化会影响绝缘子钢帽的温升;在强风条件下,各绝缘子钢帽温度相同,不适合进行绝缘子红外检测。研究成果可用于指导电网红外巡检工作,保障绝缘子红外巡检结果的正确性,从而实现电网的安全稳定运行。With the development of infrared measurement technology,insulator status detection by thermal infrared imager is applied to the daily inspection of the power grid.However,the measurement results will be affected by environmental parameters significantly.Taking porcelain insulators operating on transmission lines as the research object,infrared images of insulators are obtained in different light intensity,humidity,temperature and wind speed.The influence of environmental parameters on the detection results of insulators is studied.The results shows that the change of light intensity will lead to misjudgment when the method based on the temperature rise curve is used to detect the zero-value insulator.The change of temperature has no effect on detection of zero-value insulator,while the change of humidity will affect the temperature rise of insulator steel caps.In strong wind,the temperatures of the insulators are the same,which is not suitable for infrared detection.The research results can be used to guide the infrared inspection work of power grid to ensure the correctness of the infrared inspection on insulators,and realize the safe and stable operation of power grid.
分 类 号:TM216[一般工业技术—材料科学与工程] TP391.41[电气工程—电工理论与新技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.90