高寒地区典型办公建筑南向组合式外窗热工设计优化  

Thermal design and optimization of south-oriented combined external window for a typical office building in frigid plateau region

在线阅读下载全文

作  者:刘依明 许沛琪 刘念雄[1] LIU Yiming;XU Peiqi;LIU Nianxiong(School of Architecture,Tsinghua University,Beijing 100084,China)

机构地区:[1]清华大学建筑学院,北京100084

出  处:《清华大学学报(自然科学版)》2023年第11期1878-1886,共9页Journal of Tsinghua University(Science and Technology)

基  金:国家重点研发计划项目(2022YFC3803800)。

摘  要:为提升西藏高寒地区办公建筑的节能效果与室内使用品质,针对日喀则市某典型办公楼进行分析。借助DesignBuilder软件,对采用9种不同形式南向外窗设计的建筑案例进行建筑负荷、主要房间操作温度及热舒适的全年逐时模拟。该研究分析了各案例的性能差异,结果表明:断热桥铝合金6 mm单玻幕墙、 6 mm透明+12 mm空气+6 mm透明的中空双层窗以及保温窗帘构成的组合式外窗,能够显著降低办公楼全年负荷,并提升主要房间的室内热舒适,可作为西藏高寒地区办公建筑南向外窗设计的优先选择。[Objective]Existing design standards for energy efficiency impose rigorous static restrictions on the shape coefficient and envelope performance of buildings.However,these requirements are incompatible with dynamic adjustment to real-time changes in the weather.Thus,the loss of energy-saving effect and indoor use quality of the building proffers the potential for improvement.Therefore,this study introduces the south-oriented combined external window design for buildings based on the principle of leap heat transfer.This design improves the solar heat gain during the daytime and the insulation performance at night,which is a feasible strategy to dynamically improve the indoor thermal environment and reduce the building load.However,the effect of this design strategy on the Tibetan plateau region still needs further investigation.To improve the energy efficiency and indoor usage quality of office buildings,this study takes a typical office building in Xigaze as the object to explore the more suitable design strategies for south-oriented external windows.[Methods]This study compares nine building cases with distinct south-oriented external window designs.By quantifying the differences in building performance induced by each window design,the most efficient south-oriented external window design in the Tibetan plateau region is identified.The triple-glazing low-E windows in the baseline case meet the thermal performance requirements.In the rest of the design cases,the external window components consist of a 6 mm glass curtain wall with heat-break bridge aluminum alloy,a normal insulating window or low-E insulating window composed of two pieces of 6 mm glass and 12 mm air interlayer,and an insulating cotton curtain.DesignBuilder 6.1 is used in this study to analyze the cool and heat loads,hourly operating temperature,and thermal comfort of the primary rooms in a dynamic simulation throughout the year.Consequently,the comparison of the performance scores of nine building cases serves as the foundation for case validation

关 键 词:高寒地区 组合式外窗 太阳得热系数 建筑负荷 逐时操作温度 热舒适 

分 类 号:TU18[建筑科学—建筑理论]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象