作 者:张秀云[1] 刘洁[2] 刘珍友[2] 车紫荆 ZHANG Xiuyun;LIU Jie;LIU Zhenyou;CHE Zijing(Affiliated Qingdao Central Hospital of Qingdao University,Qingdao 266042 China;The 8th People’s Hospital of Qingdao City,Qingdao 266041 China)
机构地区:[1]青岛大学附属青岛市中心医院,山东青岛266042 [2]青岛市第八人民医院,山东青岛266041
出 处:《中国辐射卫生》2023年第4期427-432,共6页Chinese Journal of Radiological Health
摘 要:目的调查青岛市介入放射诊疗资源及防护用品和个人剂量计佩戴情况,为加强介入放射学工作人员辐射防护和健康管理提供数据支持。方法对全市范围内所有开展介入放射诊疗活动的医疗机构进行问卷调查并进行汇总分析,数据统计时间为2020年4月1日—2021年3月31日。结果青岛市共有31家医疗机构开展了放射介入诊疗。其中三级医院23家(74.20%),二级医院8家(25.80%)。全市共有介入放射诊疗设备88台,89.77%的设备位于三级医院。介入诊疗专业人员921人,其中三级医院865人(93.92%),二级医院56人(6.08%)。平均每年每千人口介入诊疗人次为5.72。个人防护用品配置率最高的为铅橡胶围裙(铅衣)、铅橡胶帽子和铅橡胶颈套,配置率均为100%。介入防护手套配置率最低,仅为51.61%。辅助防护用品配置平均每台设备均不足1件。介入放射工作人员双剂量计的佩戴率84.36%。结论青岛市开展介入放射诊疗业务的医疗机构以三级医院为主。配备的个人防护用品最多的是铅橡胶围裙、铅橡胶帽子和铅橡胶颈套,介入铅防护手套以及辅助防护设施和双剂量计的配置率偏低。Objective To investigate the current status of interventional radiology resources,radiation protection equipment,and the rate of wearing of personal dosimeters in Qingdao,China,and to provide a data basis for strengthening radiation protection and health management for interventional radiation workers.Methods A questionnaire survey was performed on all medical institutions with interventional radiation services in Qingdao.The data from April 1,2020 to March 31,2021 were pooled and analyzed.Results A total of 31 medical institutions in Qingdao were investigated,including 23(74.20%)tertiary hospitals and 8(25.80%)secondary hospitals.There were 88 pieces of interventional radiation equipment in total in Qingdao,89.77%of which were in tertiary hospitals.A total of 921 interventional professionals participated,with 865(93.92%)from tertiary hospitals and 56(6.08%)from secondary hospitals.The mean annual number of visits to interventional services was 5.72 per 1000 people.Among personal protective equipment,the equipment rates of lead-rubber aprons,lead-rubber caps,and lead-rubber collars were highest,all being 100%.The rate of equipment of interventional protective gloves was lowest,which was only 51.61%.The mean number of each accessory protective equipment for each interventional machine was less than 1.The rate of wearing of dual-dosimeters was 84.36%.Conclusion Tertiary hospitals were dominant among the medical institutions in this survey of interventional radiology services in Qingdao.The most frequently equipped personal protective goods were lead-rubber aprons,caps,and collars.The equipment rates of interventional protective gloves and protective accessories and the rate of wearing of dual-dosimeters were relatively low.
分 类 号:X591[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.38