作 者:刘芳 贾瑞瑞 邢永杰 LIU Fang;JIA Ruirui;XING Yongjie(Beijing University of Civil Engineering and Architecture,School of Environmental and Energy Engineering,Beijing 102616,China;Beijing Science and Technology Innovation Promotion Center,Beijing 100142,China)
机构地区:[1]北京建筑大学环境与能源工程学院,北京102616 [2]北京科技创新促进中心,北京100142
出 处:《建筑科学》2023年第10期113-118,125,共7页Building Science
基 金:国家重点研发计划课题“绿色智慧奥运小镇节能环保典型应用示范”(2020YFF0305504)。
摘 要:蓄热水箱是蓄热中最常见和普遍使用的装置,本文提出了1种改善蓄热水箱热分层的1种结构—弯管型进口,并对其在储热水箱中应用的放热性能开展实验研究,得到了水箱的热力学特性。基于CFD软件建立水箱的数学模型,对比实验与模拟结果基本吻合。通过对比弯管型进水结构与布水器型进水结构理查森数、热水输出率、混合数探究进水结构热分层效果。结果表明:2种进水结构混合数与理查森数相差不大,在相同工况下,弯管型进水结构的热水输出率为84.9%,布水器型进水结构的热水输出率为76.39%,在制作工艺上弯管型进水结构比布水器型进水结构简单,更易于安装。Thermal storage tanks are the most prevalent and commonly-used device category for thermal storage.This paper introduces a structure touted capable of improving the thermal stratification of thermal storage tanks—a elbow-duct inlet,and presents an experimental report of its exothermic performance in a thermal storage tank,as well as the concluded thermodynamic characteristics of the tank.The mathematical model of the tank was built using a CFD software application for the simulation,at the end of which a generally matching set of results were obtained relative to the corresponding experimental measurements.Afterwards,the thermal stratification effect of the inlet structure was further explored by comparing the Richardson number,hot water yield rate and mixing index of the elbow-duct inlet structure and a water-distributor-type inlet structure.The results show that while the difference between the mixing index and Richardson number is not significant,under the same working conditions,the hotwater yield rate of the elbow-duct inlet structure is 84.9% and the hot-water yield rate of the water-distributor-type inlet structure is 76.39%.In the production process of elbow-type water intake structure is simpler than the water distributor-type water intake structure,easier to install.
关 键 词:混合数 热水输出率 蓄热水箱 理查森数 弯管型进口结构
分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.191.28.129