一类超高层综合建筑复杂工况消防联动试验探讨  被引量:1

Discussion on Fire Protection Linkage Test under Complicated Cases of Class I Super High-rise Buildingg Complex

在线阅读下载全文

作  者:唐馨庭 唐靖松 李雅楠 TANG Xinting;TANG Jingsong;LI Ya'nan(Beijing Urban Construction Group Co.,Ltd.,Beijing 100088,China;Tsinghua University High School-wangjing,Beijing 100015,China;Beijing Urban Construction Yatai Group Co.,Ltd.,Beijing 100013,China)

机构地区:[1]北京城建集团有限责任公司,北京市100088 [2]清华大学附属中学望京学校,北京市100015 [3]北京城建亚泰建设集团有限公司,北京市100013

出  处:《建筑电气》2023年第10期15-20,共6页Building Electricity

摘  要:以某一类超高层综合建筑酒店中庭区域为例,通过模拟不同阶段、多种火灾工况下报警设备的反应时间和消防联动控制情况,测试消防报警联动控制性能和控制逻辑是否符合设计要求。In this study,the atrium area of the.hotel in a Class I super high-rise building complex is taken as an example:response time and fire-proteetion linkage control of alam equipment are simulated under different stages and multiple fire cases,so as to test whether the fire alarm linkage control performance and control logic meet the design requirements.

关 键 词:超高层建筑 酒店中庭 消防联动试验 火灾模拟 报警时间 反应时间 控制方案 火灾探测器 

分 类 号:TU892[建筑科学]

 