TR-8000血液透析机故障检查方向和解决办法  被引量:1

TR-8000 hemodialysis machine fault check direction and solution

在线阅读下载全文

作  者:李羽翠[1] 黄聪琳[2] 代保才 牟寿春 付雪松 LI Yucui;HUANG Congin;DAI Baocai;MOU Shouchun;FU Xuesong(Equipment Management Division,Gansu Provincial Hospital of TCM,Lanzhou,Gansu 730050,China;Clinical Laboratory,Gansu Provincial Hospital of TCM,Lanzhou,Gansu 730050,China)

机构地区:[1]甘肃省中医院设备管理处,甘肃兰州730050 [2]甘肃省中医院检验科,甘肃兰州730050

出  处:《中国医学工程》2023年第11期58-61,共4页China Medical Engineering

摘  要:从透析机的主要监测指标出发,分析了TR-8000型透析机的特点,以图表方式提供了该透析机的常见故障及故障检查方向,进一步结合典型实例分析了故障的解决办法,有利于工程技术人员第一时间把握维修方向,提高维修效率。Starting from the main monitoring indicators of the dialysis machine,the characteristics of TR-8000 dialysis machine were analyzed,and the common faults and fault inspection directions of the dialysis machine were provided in the form of charts,and the solution of the fault was further analyzed in combination with typical examples,which was conducive to engineers and technicians to grasp the maintenance direction at the first time and improve maintenance efficiency.

关 键 词:故障 电导度 透析液 流速 平衡腔 

分 类 号:R197.39[医药卫生—卫生事业管理]

 