检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:夏梦涛 李明鸿[1,2] 宗周红[1,2] 甘露[1,2] 黄杰 李卓[1,2] XIA Mengtao;LI Minghong;ZONG Zhouhong;GAN Lu;HUANG Jie;LI Zhuo(Engineering Research Center of Safety and Protection of Explosion and Impact of Ministry of Education,Southeast University,Nanjing 211189,Jiangsu,China;School of Civil Engineering,Southeast University,Nanjing 211189,Jiangsu,China)
机构地区:[1]东南大学爆炸安全防护教育部工程研究中心,江苏南京211189 [2]东南大学土木工程学院,江苏南京211189
出 处:《爆炸与冲击》2023年第11期12-25,共14页Explosion and Shock Waves
基 金:国家自然科学基金(51678141,52208469);中国博士后科学基金(2020M681459,2022T150119);江苏省自然科学基金(BK20220850)。
摘 要:为提升装配式公路桥梁的抗爆防护能力,提出将双层钢管混凝土柱应用于桥梁下部结构的预制节段拼装墩柱体系。对预制节段拼装双层钢管混凝土墩柱(precast segmental concrete-filled double-skin steel tube,PS-CFDST)进行了大当量野外爆炸试验,并基于LS-DYNA软件建立了精细化有限元模型,对PS-CFDST柱在爆炸荷载作用下的动力响应和破坏过程进行了数值模拟。结果表明:大当量地面爆炸作用下,PS-CFDST柱的破坏模式表现为后张预应力筋断裂引起的墩柱整体失效,地面爆炸作用下墩柱在墩身底部接缝有较大的剪切滑移,核心混凝土的损伤主要出现在接缝处和预应力筋挤压处;预应力筋的建模方式对预制节段拼装墩柱的动力响应具有显著影响;增大轴向荷载可以减小预制节段拼装墩柱的侧向变形和墩底剪切滑移,有利于提高墩柱的抗爆性能。In order to improve the blast resistant performance of prefabricated highway bridges,a precast segmental concretefilled double-skin steel tube(PS-CFDST)column was developed.A large equivalent field blast test on the PS-CFDST columns was conducted and a high-fidelity finite element model was established using LS-DYNA to simulate the dynamic response and failure mode of the PS-CFDST columns under blast loading.The experimental and numerical results demonstrated that the failure mode of the PS-CFDST columns under large equivalent surface explosion was fracture failure of prestressing tendons induced loss of column integrity.The PS-CFDST column exhibited large shear slippage at the column bottom segment-tofooting joint.The damage to core concrete was concentrated at the joints and contact areas between segment and prestressing tendons.The modeling approaches for prestressing tendons have a significant influence on the dynamic response of the PSCFDST columns.Increasing axial loads can effectively mitigate the column lateral deflection and shear slippage at the column bottom and it is beneficial to improve the blast resistance of the PS-CFDST columns.
关 键 词:预制节段拼装双层钢管混凝土柱 大当量爆炸试验 破坏模式 预应力
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.224.93.225