检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:吴璐子 WU Luzi(Office of Laboratory and Facility Management,Minjiang University,Fuzhou,Fujian 350108,China)
机构地区:[1]闽江学院实验室与设备管理处,福建福州350108
出 处:《闽江学院学报》2023年第5期81-90,共10页Journal of Minjiang University
摘 要:分布式电源(distributed generation,简称DG)接入导致传统配电网故障选线算法适用性受限,通过零序电流特征分析,利用小波包细节分解算法高阶细节分量DD5,提出基于首端零序电流突变量与突变极性比较的双重选线判据,在PSCAD/EMTDC上搭建含分布式电源配电网仿真模型,验证所述方法在单相接地故障时能够准确定位故障线路,具备一定的耐过渡电阻能力,且方法同样适用于无源配电网。The access of distributed generation(DG)leads to the limitation of the applicability of the traditional fault line selection algorithm for distribution network.Through the analysis of zero-sequence current characteristics,using the high-order detail component DD5 of wavelet packet detail decomposition algorithm,a double line selection criterion based on the comparison of the zero-sequence current mutation and the mutation polarity at the head end is proposed.The simulation model of distribution network with distributed generation is built on PSCAD/EMTDC.It is verified that the method described in this paper can accurately locate the fault line when single-phase ground fault occurs,and has a certain ability to withstand transition resistance,and the method is also suitable for passive distribution network.
关 键 词:分布式电源(DG) 小波分析 单相短路 故障选线
分 类 号:TM773[电气工程—电力系统及自动化]