摘 要:检测实验室中A和B两台棒材水浸探伤设备的旋转装置参数设定采用不同方式,A设备采用线速度,B设备采用转速度,因此两台设备检测同一支试样时,在其他参数相同的条件下探伤时间存在差异。研究分析两台设备之间的差异性,优化了每台设备的检验产品尺寸规格区间,利用设备自身优势,合理使用设备,提升设备检测效率。In the testing laboratory,A and B bar immersion flaw detection equipment have different rotation device parameters.Equipment A uses linear speed,and equipment B uses rotational speed.Thus,when the same sample are tested by the two equipment,the flaw detection time is different under the condition of the same parameters.The differences between the two equipment are analyzed,and the interval of inspection of the product size specifications for each equipment is optimized.The testers can make fully use of the equipment itself to rationally use the equipment,and improve the testing efficiency of the equipment.